background image

service data sheet

241868703

ice & Water - aUtOMatic deFrOst

side BY side - r134a 

iMpOrtant saFetY nOte

The information provided herein is designed to assist qualified 
repair personnel only. Untrained persons should not attempt to 
make repairs due to the possibility of electrical shock. Disconnect 
power cord before servicing this appliance.

iMpOrtant

If  any  green  grounding  wires  are  removed  during  servicing, 
they  must  be  returned  to  their  original  position  and  properly 
secured.

 

caUtiOn

all electrical parts and wiring must be shielded from torch 
flame. dO nOt allow torch to touch insulation; it will char 
at 200°F and flash ignite (burn) at 500°F. excessive heat will 
distort the plastic liner.

nOte

This product comes equipped with an Adaptive Defrost Control 
(ADC). To  activate  manual  defrost,  simultaneously  press  and 
hold the Fresh Food up (+) and Fresh Food down (-) keys for 5 
seconds. A “d” in the freezer temperature window and “F” in the 
refrigerator temperature window will display when the heater is 
activated. To  deactivate  manual  defrost,  simultaneously  press 
and hold the Fresh Food up (+) and Fresh Food down (-) keys 
for 5 seconds. A “d” and “F” will be displayed until the defrost 
cycle is complete.

ice maker information

test cycling

Press the momemtary contact on the ON/OFF switch 
for approximately 15 seconds. Ice maker will continue to 
complete the cycle.

Water Fill volume

Remove cover by inserting screwdriver in notch at bottom and 
prying cover from housing. The water fill adjustment screw 
will change the fill time. One turn is equal to 20cc (.68 oz.). 
The correct fill is 102 to 110cc (3.25 to 3.5 oz.). When a water 
valve is replaced, the fill volume must be checked.

TUR

N

Mounting
Plate
Screws

Mounting

Plate

Screw

Motor
Gear

Timing

Gear

Water Fill
Adjustment

Ice Maker
ON/OFF
Switch

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT                           

CONTROL SETTING

Type A with Run/Start           
Capacitor

65°F (18°C) Ambient

90°F (32°C) Ambient

Variable Speed

Standard

Variable Speed

Standard

Operating Time

74 to 84%

32 to 40%

100%

55 to 65%

Freezer Temperature

-2° to 2° F  

-19° to -17° C

0° to 4° F    

-18° to -16° C

-1° to 3° F  

-18° to -16° C

-1° to 3° F    

-18° to -16° C

Refrigerator Temperature

34° to 39° F   

1° to 4° C

34° to 39° F   

1° to 4° C

34° to 39° F   

1° to 4° C

34° to 39° F    

1° to 4° C

Low Side Pressure  
(cut-in)

5 to 12 psig  

43 to 83 kPa

5 to 12 psig   

43 to 83 kPa

N/A

5 to 12 psig    

43 to 83 kPa

Low Side Pressure      
(cut-out)

-2 to 2 psig  

-14 to 14 kPa

-2 to 2 psig  

-14 to 14 kPa

-2 to 2 psig  

-14 to 14 kPa

-2 to 2 psig    

-14 to 14 kPa

High Side Pressure               
(last 1/3 cycle)

90 to 105 psig  

621 to 724 kPa

90 to 115 psig  

621 to 793 kPa

120 to 135 psig  

827 to 931 kPa

130 to 155 psig 

896 to 1069 kPa

Wattage (last 1/3 cycle)

60 to 65

120 to 150

65 to 80

130 to 160

Amps (running)

.7 to 1.1

1.0 to 1.4

.9 to 1.3

1.1 to 1.5

Base Voltage

115 vac (127 vac max)

deFrOst speciFicatiOns

Cabinet Size

thermostat

heater

Cut-in

Cut-out

Watts

Ohms

23’, 23’ CD, 26’

25° F (-4° C)

47° F (8° C)

450

30

Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.

cOndenser Fan MOtOr

Watts

rpM

amps

3.1

1100 CW Opposite Shaft

0.03 Running

ice MaKer speciFicatiOns

Electrical

115 vac (127 vac max)

Thermostat

Opens at 48° F ( 9° C), Closes at 15° F ( -9° C)

Heater Voltage

85 vac

ice MaKer cOnnectOr pLUG cOnnectiOns

Wire number

Wire color

connects to:

1

Green/Yellow

Ground

2

Yellow

Water Valve

3

Black

Line

4

Light Blue

Neutral

iMpOrtant: pLease retUrn this sheet tO 