1.4 Warnings 

 

  The  installation  of  Inverell  /  I7000  burner  may  require  a  building  consent  prior  to  installation 

commencing.    Check  with  your  local  Building  Authority  whether  there  are  any  extra  requirements 
before commencing installation. 

  The  Inverell  /  I7000  burner  and  flue  system  shall  be  installed  in  accordance  with  AS/NZS 

2918:2001 and appropriate requirements of the relevant local building codes.   

  Glen  Dimplex  highly  recommends  NZHHA  trained  SFAIT  (Solid  Fuel  Appliance  Installation 

technician) installer for installation of Inverell / I7000 burner.  Your dealer or heating specialist will 
be  able  to  help  with  recommendations  as  well  as  advice  on  permits/consents  required  for  the 
installation in your area.  

  Please  read  carefully  all  the  dimensions  and  recommendations  provided  in  this  manual.    The 

dimensions given comply with required safety standard AS/NZS 2918:2001.  

  Safety and emissions performance of Inverell / I7000 can be affected by altering the appliance hence no 

modifications are allowed without written permission from the manufacturer. 

  Please  ensure  that  only  components  approved  by  Glen  Dimplex  New  Zealand  are  used  for  the 

installation,  as  substitutes  may  adversely  affect  performance  and  might  nullify  compliance  with  the 
requirements of AS/NZS 2918 safety standard. 

  Inverell / I7000 burner should be installed with a Masport flue system or equivalent and compliant to 

AS/NZS 2918:2001.   

  Modifying  the  dimensional  specification  of  components  may  result  in  hazardous  conditions.  Where 

such action is considered, the manufacturer should be consulted in the first instance. 

  Inverell  /  I7000  burner  and  flue  system  must  be  serviced  at  least  once  a  year  or  more  frequently 

depending upon usage.  

 

1.5 Caution 

 

  This  appliance  is  not  intended  for  use  by  persons  (including  children)  with  reduced  physical, 

sensory,  or  mental  capabilities,  or  lack  of  experience  and  knowledge,  unless  they  have  been 
given  supervision  or  instruction  concerning  use  of  the  appliance  by  a  person  responsible  for 
their safety. 

  Do  not  leave  children  un-attended  near  alighted  fire  and  keep  them  well  away  from  the  fire 

when in use. Supervise young children to ensure that they do not play with the appliance. 

  Do  not  use  flammable  liquids  or  aerosols  to  start  or  rekindle  the  fire.    Also,  do  not  use  such 

flammable materials near this appliance when it is operating. 

  Always  keep  clothing,  firewood,  furnishing  and  other  combustible  materials  at  a  safe  distance 

from the fire. 

  Cracked/broken door glass, makes the installation unsafe.  Do not operate the fire with cracked 

glass. 

  Do  not  attempt  to  clean  or  maintain  the  fire  when  in  use  or  with  hot  embers  in  the  firebox. 

Ensure that embers and all other parts of the fire have cooled down completely before starting 
ash removal or other maintenance.  

  Do  not  use  the  fire  if  there  is  a  malfunction,  a  suspicion  of  breakage  or  unusual  noises.  

Contact your nearest Masport dealer or customer service team at Glen Dimplex New Zealand. 

  This  appliance  should  always  be  installed,  operated  &  maintained  as  per  instructions  given  in 

this manual. 
 

 
 

 

 

Failure to follow above warnings, cautionary measures 

and instruction given in this installation and operation 

manual will void the Masport warranty of this product. 

 

Summary of Contents for I7000

Page 1: ...FUTURE REFERENCE Manufactured in New Zealand by GLEN DIMPLEX NEW ZEALAND LIMITED P O Box 58473 Botany Manukau 2163 Ph 0800 666 2824 Fax 09 274 8472 Email sales glendimplex co nz Web www glendimplex co...

Page 2: ...PECIFICATIONS 5 3 0 WORKING PRINCIPLE OF INVERELL I7000 6 4 0 LOCATION OTHER IMPORTANT CONSIDERATIONS 7 5 0 INSTALLATION PROCEDURE FOR INVERELL I7000 9 5 1 BUILT IN FRAMING 9 5 1 1 MINIMUM CLEARANCES...

Page 3: ...s are heavy and tall in size with a total weight of 190 kg Single person handling could cause injury hence Masport recommends suitable handling equipment or two persons while handling both outside and...

Page 4: ...action is considered the manufacturer should be consulted in the first instance Inverell I7000 burner and flue system must be serviced at least once a year or more frequently depending upon usage 1 5...

Page 5: ...along with the flexible ducting fitted to its outer casing The ducting is then vented into the living room or adjacent room In both Australia and New Zealand Inverell I7000 has been tested to and com...

Page 6: ...es around this superhot firebox absorbs heat energy from its outer surfaces and becomes hot to a significant level This hot air rises and exist the zero clearance cabinet through two circular ports lo...

Page 7: ...stalled at an elevated height floor protector requirement depends upon the elevation of fire above ground Support shelf can be maximum up to height of 670mm above the ground Floor protector For an ele...

Page 8: ...be minimum 18 mm thick non combustible material like Promina or equivalent For front side faces of built in cavity use minimum 9 mm thick non combustible material like Promina or equivalent For front...

Page 9: ...5 0 Installation Procedure for Inverell I7000 burner 5 1 Built in Framing DO NOT FIX CLADDING UNTILL FIRE DUCTINGS AND VENTS ARE FULLY INSTALLED Page 9...

Page 10: ...5 1 1 Minimum clearances of built in enclosure to combustibles Page 10...

Page 11: ...by lifting and tilting from the hinge block Keep it away in safe place Take out carton box and keep its contents in safe place Take out 2 x semi rigid Aluminium ducts Remove 4x taptite screws two on...

Page 12: ...lize the entire fire horizontally within the built in cavity Simultaneously using piece of non combustible front cladding material as a gauge position the flanges of fascia forward out of cavity face...

Page 13: ...utout on front side and rear of the built in cavity for air inlets and outlets Air inlet holes need to be minimum 26000 mm2 open area each on side and rear of cavity approx 50mm above support shelf Us...

Page 14: ...ng front or side of the cavity Place the template on the front cladding mark and cut required cutout Use 2x self tapping screw and attach template to front cladding on two sides Drill four dia 4 5 top...

Page 15: ...ed by flue manufacturer Top of the built in cavity or chimney chase must be ventilated either using 300mm dia additional casing or side vent at the top of cavity To begin fix the ZC flue kit adaptor u...

Page 16: ...5 7 Floor Protector Use diagram below to install required floor protection Page 16...

Page 17: ...ring handing and installation of the fire For operations maintenance trouble shooting and warranty terms use Owner s Manual supplied along with the fire Important For any installation variations other...

Reviews: