background image

OPERATING INSTRUCTIONS

BASIC INFORMATION

DOOR HANDLE Arcadia: Swing the door open and shut with the handle in the 3
o’clock position. Latch the door shut by pushing in on the handle and turning it toward
the 6 o’clock position.
Utopia: This model has twin doors with a central latching system. To keep the handle
cool it is detachable, and it should be engaged with the latching system only when
opening or closing the doors. The doors are opened and closed with the handle in the 1
o’clock position. Turn the handle fully clockwise (to about the 6 o’clock position) to
latch the doors shut. Use the loose handle to swing the left hand door into position for
latching. Do not touch the doors by hand as they can be very hot.

HEAT OUTPUT CONTROLS Two types of air control are provided — the upper air
control and the twin lower air vents in the door. Opening the lower vents (two turns
anti-clockwise) for a few minutes when loading wood fuel will assist rapid ignition.
The lower vents should then be closed unless maximum heat output is required. The
upper air control moves toward the right to increase the heat output and toward the left
to decrease it. A high fire can be shut down rapidly only by starving it of air, and this
can result in undesirable emissions. For this reason, Masport heaters are designed to
settle down to lower heat outputs comparatively slowly.

EXTENDED BURN TIMES  To obtain maximum burn times a generous quantity of
wood should be banked up on top of a healthy ember bed and allowed a few minutes to
achieve ignition. All air controls should then be closed. Hardwoods will always give
longer burn times than softwoods.

ESSENTIAL ADVICE

• Correct installation, the use of only DRY wood and adherence to the following
instructions will ensure satisfactory performance. The use of wood with greater than
25% moisture is not permitted.
• MAKE SURE THE MINIMUM HEATER-TO-WALL DISTANCES SHOWN ON
PAGE 4 ARE ALWAYS MAINTAINED BETWEEN THE HEATER AND ANY
HEAT SENSITIVE MATERIAL SUCH AS FURNITURE, WINDOW DRAPES,
FUEL ETC.
• DO NOT ATTEMPT TO BURN LIQUID FUELS OF ANY KIND.

LIGHTING UP

Before lighting the first fire, spread the sand provided over the floor of the firebox
evenly. This applies equally to woodburners and coal-type burners. Subsequently,
always leave sand or ash to the level of the tops of the floor ribs.
Slide the upper air control fully to the hot position (the right). The two lower air vents
in the door may be opened two turns to assist rapid ignition.

Crumple up several double sheets of newspaper and place them in the centre of the
firebox or the grate. Build a pyramid of thin, dry kindling wood on the paper with some
heavier pieces on top. Light the paper at the bottom and leave the door slightly ajar
until the kindling has ‘caught’, then latch the door shut.

WARNING: DO NOT USE ANY FLAMMABLE LIQUID SUCH AS
PETROL, KEROSENE, OIL ETC. TO START OR REKINDLE THE FIRE.

When the kindling is well alight, open the door slowly and add some larger pieces of
wood. Close and latch the door. Once these are properly alight, the final fuel can be
carefully laid on the fire-bed.
Move the heat output controls away from the maximum settings only after the fire is
well established. We recommend running at full heat for 30 minutes after lighting. The
controls can then be set wherever desired. If maximum heat output is not required,
close the two lower air vents. Until the heater has been run for a total of 8 hours, it
should not be operated at more than half heat output from thirty minutes after  light-up.

The special high temperature paint on the firebox will emit some smoke as it cures
during the first hour or so of running. This is quite normal.

                                                             10

Summary of Contents for ARCADIA

Page 1: ...ARCADIA UTOPIA UTOPIA Series 2 GRAND UTOPIA SOLID FUEL HEATERS INSTALLING AND OPERATING INSTRUCTIONS 585877 ...

Page 2: ...ou should approach your local Building Authority before commencing installation to establish whether you will require a Permit and whether you will need to meet extra requirements MASPORT radiant heaters have been tested to ensure that they will meet the appropriate safety Standard requirements if the instructions in this book are followed PLEASE ENSURE THAT ONLY COMPONENTS APPROVED BY MASPORT ARE...

Page 3: ...lign with the back edge of the top of the heater and the extension should fit snugly against the top casting Raise the heater into its upright position again taking care not to damage the floor Before fitting the firebox ceiling baffle first locate the four support lugs which will support it near the top of the firebox Insert the baffle into the firebox ensuring that the curved centre section is a...

Page 4: ...nts for a fireplace installation Finalise the installation position for your woodfire only after considering the necessary heater to wall distances see below and checking the practicability of installing the flue system through the ceiling and roof or wall As a guide the flue shielding and the 25mm clearance gap around it in the ceiling space will occupy a diameter of approximately 300mm and this ...

Page 5: ... 25 mm2 i e 15 000mm2 So if the effective length of each slot is 1m it will need to be 15mm wide Three types of shield are recommended Type Layers Spacing Clearance Factor A One 12mm 0 4 B One 25mm 0 3 C Two 12 12mm 0 2 Valid only for shields within 45 of vertical To find the reduced minimum distances multiply the figures in columns A B and E from the Table on page 4 by the appropriate clearance f...

Page 6: ...A G H J G l a ss W 360 min Wall Minimum dims for A are on page 4 See Notes below MINIMUM HEARTH EXTENSIONS mm WHEN THE REAR HEAT SHIELD IS FITTED Rear Heat Shield W B C D G H J Australia New Zealand New Zealand hearth flush hearth 50mm high Arcadia Utopia Arcadia Utopia Arcadia Utopia 855 635 300 165 150 335 525 1075 760 425 275 150 335 525 975 680 345 225 150 335 525 1165 980 550 275 155 430 615 ...

Page 7: ...X Y NOTE YOUR SPECIFIC MEASUREMENT FOR E MUST BE ADDED TO X AND Y TO FIND THE APPROPRIATE MINIMUM HEARTH DIMENSIONS SEE PAGE 4 FOR MINIMUM VALUES OF E MINIMUM DIMENSIONS Millimetres Australia 750 430 New Zealand hearth 50mm high New Zealand hearth flush Arcadia Utopia Utopia Utopia Arcadia Arcadia 800 540 750 470 1050 730 1000 680 850 550 HEARTH CONSTRUCTION In Australia the minimum hearth constru...

Page 8: ...Australia Not less than 18mm thickness of fibre cement board New Zealand Two sheets of MICORE160 or one sheet of WOODTEX 35 thick Ceramic tiles Trim moulding Recommended hearth constructions are FITTING A WATER COIL Water heating coils can be fitted to Arcadia and Utopia heaters The pipe attachment positions are shown below B Heater A B Arcadia Utopia 280 310 590 520 C Alternate flue position at r...

Page 9: ...apter 7 1985 except that the specified separation between the outside of the chimney and timber construction need not be complied with A flue pipe must be fitted right up the chimney and the space between the flue pipe and chimney must be ventilated at the top In Australia the area of this vent must be not less than 10 000mm2 while in New Zealand it is 13 000mm2 The vent must be fitted with means ...

Page 10: ...ing instructions will ensure satisfactory performance The use of wood with greater than 25 moisture is not permitted MAKE SURE THE MINIMUM HEATER TO WALL DISTANCES SHOWN ON PAGE 4 ARE ALWAYS MAINTAINED BETWEEN THE HEATER AND ANY HEAT SENSITIVE MATERIAL SUCH AS FURNITURE WINDOW DRAPES FUEL ETC DO NOT ATTEMPT TO BURN LIQUID FUELS OF ANY KIND LIGHTING UP Before lighting the first fire spread the sand...

Page 11: ...LED YOU MAY HAVE TO LEAVE A DOOR SLIGHTLY OPEN AND PERHAPS A WINDOW ELSEWHERE IN THE HOUSE IF YOUR HOME IS OF MODERN AIRTIGHT CONSTRUCTION LEAVING THE DOOR OPEN WILL HELP SPREAD WARMTH THROUGH THE REST OF YOUR HOME SAFETY Always keep children well away from the heater when it is alight as surfaces on radiant heaters can become very hot If children or aged and infirm persons might accidentally touc...

Page 12: ...sote and soot build up are inadequate draught smoking when the door is opened and a dull thud when the outside of the flue is tapped A blocked flue can be cleaned only by sweeping DO NOT USE CHEMICAL CHIMNEY CLEANERS To facilitate flue cleaning the firebox ceiling baffle should be lifted out See ASSEMBLY page 3 for instructions on re fitting the baffle correctly CLEANING THE HEATER Usually a wipe ...

Reviews: