background image

 

 

 

Ref No.: m92A/om/101 

 

                                                                                                                                                         Issue No.: 15 

 

3 | 

P a g e

 

 

9000 U 

C

ONFIGURATION 

 

 

Front Element of SOP/DOP 

 

 

      

Front Element of TOP/FOP

 

 
 

 
 

 

 

 

 
 

 

 
SAFETY

 

AND

 

WARNING

 

 

 

To ensure that the device can be operated safely and all 
functions can be used, please read these instructions 
carefully. 
 

 

Caution: Never carry out work when the Power 
is turned on, this is dangerous.   
 

 
Installation and startup 
must be carried out by qualified 
personnel only.

 

The relevant country-specific regulations 

(e.g., VDE, DIN) must also be observed.    

 

Before startup it is particularly important to ensure:  
 
• Terminal wiring: 
   Check that all cables are correctly connected according to 
   the connection diagram  

 

 The mains has been connected correctly and protection is  

   provided against electric shock.  
• The device can be switched off outside the power supply  
   according to EN 60950 regulations (e.g., by the line  

   protection on the primary side)    
• All supply lines should have sufficient fuse protection and 
  are of correct size. 
• All output cables are of correct size for the maximum 
  device output current or have separate fuse protection. 
• Sufficient convection is ensured. 
 
   After installation the terminal area must be covered to  
   provide sufficient protection against unauthorized access  
   to live parts. 
   This is ensured by installing the device in the control 
   cabinet or distributor box. 
 

  

I

NSTALLATION

 

 

 

Mounting On DIN Rail – 9000U

 

 8 5 V -2 6 5 V AC

4 5 -6 5 Hz

1 0 0 -3 0 0 VDC

 8 5 V -2 6 5 VAC

4 5 -6 5 Hz

1 0 0 -3 0 0 VDC

 8 5 V -2 6 5 V AC

4 5 -6 5 Hz

1 0 0 -3 0 0 V DC

 

 Environment: 
 

     
    Mounting: 
 
    The unit can be snapped onto all DIN rails according to  
    EN 60715. The device must be mounted horizontally 
    (Input terminal blocks facing downwards)             
 

  Installation Dimensions: 
 

 

To ensure sufficient convection, a minimum 

  spacing of 3 cm is required. 

 

      Place the module with the DIN rail guide way on the                                  
      bottom edge of the DIN rail and then snap it downwards.  
      
The housing is mounted on the DIN rail by swiveling it                        
      into place. 
 

 As air vents are provided on the top and bottom part of the 
 unit, the (horizontal) mounting arrangement allows good     
 vertical air circulation.     
 

 

Vertical mounting arrangement of multiple            
units must be avoided.    
 

 

      Removal: 
      Release the snap-on catch using a screwdriver and then  
      detach the module from the bottom edge of the DIN Rail.    

C

ONNECTING DIAGRAM

 

 

Item 

nos. 

Details 

1,2  

Aux. Supply(L,N) 
DC+,  DC-  (In  case  of 
DC Supply) 

6,7 

24VDC TPS - / + 

8, 9 

Input + / -  (V, mA) 

13, 14 

Output2 - / + (V, mA) 

17, 18 

Output1 - / + (V, mA) 

21 

Power On  
RED LED 

22 

Output1 On 
Green LED 

23 

Output2 On  
Green LED 

Zero adjustment Pot 
for O/P1 and O/P2 

Span adjustment Pot 
for O/P1 and O/P2 

 

 

Item 

nos. 

Details 

2,3  

Aux. Supply(L,N) 
DC+,  DC-  (In  case  of 
DC Supply) 

13,14 

24VDC TPS - / + 

15, 16 

Input + / -  (V, mA) 

23, 22 

Output4 - / + (V, mA) 

27, 26 

Output3 - / + (V, mA) 

33, 32 

Output2 - / + (V, mA) 

37, 36 

Output1 - / + (V, mA) 

39 

Power On  
RED LED 

40 

O/P1,O/P2,O/P3, 
O/P4  
On Green LED 

Zero adjustment Pot 
for O/P1,O/P2,O/P3, 
O/P4 

Span adjustment Pot 
for  O/P1,O/P2,O/P3, 
O/P4 

 

Caution:  Do  not  install  the  unit  where  it  is 
subjected to continuous vibration. 
Do not subject the unit to physical impact.   
 

 85V-265VAC

45-65Hz

100-300VDC

Reviews: