12
DOOR ADJUSTMENTS
Door Adjustments
(MLCR215, MOCR215 & MACR215)
HINGE COVER
Hinge cover included with the literature bag is optional.
To install hinge cover:
• Press hinge cover squarely over hinge.
Door Alignment and Adjustment
Align and adjust the door if it is not level or is not sealing
properly. If the door is not sealed, the unit may not cool
properly, or excessive frost may form in the interior.
Properly aligned, the door’s gasket should be firmly in
contact with the cabinet all the way around the door (no
gaps). Carefully examine the door’s gasket to ensure that
it is firmly in contact with the cabinet. Also make sure the
door gasket is not pinched on the hinge side of the door.
To align and adjust the door
1.
Gently pry off hinge cover from top of unit.
2. Loosen (do not remove) top and bottom hinge screws
using a Torx T-25 screwdriver.
3. Align door squarely with cabinet.
4.
Make sure gasket is firmly in contact with cabinet all
the way around the door (no gaps).
5. Tighten bottom hinge screws.
6. Tighten top hinge screws and replace hinge cover.
Hinge Cover
Figure 18
NOTE
Door Adjustments
(MACR214)
CHECKING DOOR ALIGNMENT
The unit’s door is aligned at the factory before shipment.
However, its alignment could have been disturbed during
shipment.
Door Alignment and Adjustment
To align and adjust the door
1. Loosen (do not remove) top and bottom hinge screws.
2. Align door squarely with cabinet. Make sure gasket
is firmly in contact with cabinet all the way around the
door (no gaps).
3. Tighten bottom hinge screws.
4. Tighten top hinge screws.