Entire Product
Limited One Year Parts and Labor Warranty
Marvel warrants that it will supply all necessary
parts and labor to repair or replace in the end
user's home or office, any component which
proves to be defective in material or workmanship,
subject to the condition and exclusions stated
below, for a period of one year from the date of
purchase by the end user.
Additional Second Through Fifth Year
Limited Parts Only Warranty
During the four years following expiration of the
one year limited warranty, Marvel will supply
replacement parts for the hermetically sealed
refrigeration system which consists of the com-
pressor, condenser, drier, accumulator, by-pass
valve, connecting tubing and the evaporator that
are proven to be defective due to workmanship or
materials subject to the conditions and exclusions
below.
The above warranties do not cover:
• Shipping costs of replacement parts or returned
defective parts.
• Customer education or instructions on how to
use the appliance.
• Any content loss due to product failure.
• Removal or installation.
Nor do the above warranties cover failure of this
product or its components due to:
1. Transportation or subsequent damages.
2. Use commercially or use other than normal
household or small office.
3. Improper installation, misuse, abuse, accident
or alteration, use on wiring not conforming to
electrical codes, low or high voltages, failure to
provide necessary maintenance, or other unrea-
sonable use.
Parts or Service
Not Supplied or Designated by Marvel
The above warranties also do not apply if:
The original bill of sale, deliver date or serial num-
ber cannot be verified.
Defective parts are not returned for inspection if so
requested by Marvel.
The refrigeration equipment is not in the posses-
sion of the original end use purchaser.
The warranties set forth herein are the only war-
ranties extended by Marvel Industries. Any implied
warranties, including the implied warranty of mer-
chantability, are limited to the duration of these
express warranties. In no event shall Marvel
Industries be liable for any consequential or inci-
dental damages or expenses resulting from
breach of these or any other warranties, whether
express or implied.
Some states do not allow the exclusion or limita-
tion of consequential damages or a limitation on
how long an implied warranty lasts, so the above
exclusion or limitation may not apply to you. This
warranty gives you specific legal rights and you
may have other rights that may vary from state to
state.
No person, firm, or corporation is authorized to
make any other warranty or assume any other
obligation for Marvel Industries. These warranties
apply only to products used in any of the fifty
states of the United States and the District of
Columbia.
To obtain performance of this warranty, report any
defects to:
Marvel Industries
P.O. Box 997
Richmond, Indiana 47375-0997
Phone: 765-962-2521
12
WA R R A N T Y
PROBLEM
Ice is not clear.
Low ice production. Unit is running,
has run over a 48 hour period, and
there is little ice in bin.
Unit continues to run and produce
ice.
Grid-cutter is not cutting the ice
slab.
T R O U B L E S H O O T I N G T H R E E
15
POSSIBLE CAUSE
Low water level in reservoir.
Softened water supply.
Room temperature is too cold.
Low water level in reservoir.
Distributor tube is restricted.
Build up of deposits on evaporator plate.
Inadequate drain system.
Condenser fan air flow is restricted.
Ice bin is not full.
Ice bin is full.
Room temperature is too warm.
Ice machine is not level.
The selector switch is not in the "ON"
position.
The grid cutter is not plugged into the
receptacle.
Time to cut through the slab
CORRECTION
Make sure that the reservoir drain plug is installed properly.
Check the water line to the unit to make sure there are no
restrictions or kinks in the line. Check all filters to make
sure they are not restricted or plugged.
Make certain that water line is not connected to the water
softener.
Move the unit to an area where room temperature is above
55° F.
Make sure that the reservoir drain plug is installed properly.
Check the water line to the unit to make sure there are no
restrictions or kinks in the line. Check all filters to make
sure they are not restricted or plugged.
See "CLEANING YOUR ICE MACHINE" section for clean-
ing the unit for proper operation.
Restriction in drain lines will cause ice in the bin to melt. If
using a gravity drain, make certain there are no kinks or
restrictions in the drain lines. If using a drain pump, check
the inlet screen, discharge line, and vent line for any build-
up or restrictions.
Make certain the grille in the front of the unit is free and
open for proper air circulation. Check and clean the con-
denser coil by removing the grille in the front of the unit.
Clean the condenser with a vacuum and brush attachment.
The unit will automatically shut down when ice reaches the
sensing tube.
The unit will automatically shut down when ice reaches the
sensing tube and has completed the harvest of the ice slab.
Move the unit to an area where room temperature is below
90° F.
Use a level to check the unit for level from side to side and
front to rear.
Set the rocker switch on the grille of the ice machine to the
"ON" position.
Remove the escutcheon panel and plug the grid-cutter into
the receptacle on the side of the line.
It can take up to 35 minutes to cut through a harvested ice
slab. This is normal operation.