P R E PA R I N G   Y O U R   I C E   M A C H I N E   F O R   S T O R A G E

Storage of Ice Machine

If the ice machine is to be moved, not used for an
extended time or will be in an area that will be
near freezing temperatures – below 37° F, it is
necessary to remove the remaining water in the
ice-making system. 

Cleaning of Ice Machine for Storage

Cleaning the ice machine will prevent mold and
mildew growth as well as sanitize the unit for stor-
age or when it is put back into service.

1. Remove all ice from the ice storage bin.

2. Pull the reservoir drain plug to drain reservoir.

3. Reinstall the drain plug after all of the water

has drained.

4. Add ice machine cleaning solution to ice

machine’s reservoir. Refer to the machine
care section of guide for further information.

5. Switch the rocker switch in the grille to

“CLEAN” position.

6. The clean cycle will complete in 50 minutes.

Draining and Removing Water from System

1. Turn off the water supply to the ice machine.

2. Disconnect the water supply fitting at the inlet

of the water valve.

3. Switch rocker switch to “CLEAN” for about 1

minute. This will energize and open the water
valve and remove most of the water from the
valve and the outlet water line to the reservoir.

4. Switch rocker switch to “OFF” position. This will

energize and open the drain valve to drain the
reservoir and the ice machine drain system.

5. Unplug the unit from the electrical outlet.

6. Remove back panel from the rear of the unit.

7. Disconnect the water valve’s outlet water line

to the reservoir and drain the remaining water
left in the water line trap area.

8. Reconnect water valve outlet water line and

tighten compression nut to a watertight seal.

9. Reinstall the unit’s back panel.

10. Clean and dry the ice storage bin.

11. Prop the door open for air circulation and to

prevent mold and mildew.

12. Leave water supply line disconnected or, if

reconnect, leave it shut off. DO NOT turn the
water on and allow water to enter the valve.

Draining Water for Optimal Drain Pump Life

1. Remove the drain pump from the ice machine

(refer to drain pump installation instructions).

2. Drain the water in the drain pump’s reservoir

by turning the pump upside down and allow-
ing water to drain through the pump’s inlet and
vent tube fittings.

3. After all water is drained, reinstall the drain

pump. Make certain all tubing is installed and
all hose clamps are tight (refer to drain pump
installation instructions).

Restarting the Ice Machine

1. With the rocker switch in the “OFF” position,

plug the unit into an electrical outlet.

2. Reconnect or turn on the water supply line.

3. Reconnect the drain tubing if removed.

4. Turn the rocker switch to the “ON” position.

5. Check the water inlet, drain lines, and fittings

for any water leaks.

6. Check drain pump (if equipped) operation by

pouring approximately 2 quarts of water into
the ice storage bin. The drain pump should
activate and discharge water (refer to drain
pump installation instructions). Check for
water leaks at all hose connections.

ALL WATER MUST BE DRAINED AND REMOVED TO PREVENT
ICE MACHINE DAMAGE AND POSSIBLE WATER DAMAGE TO 
THE SURROUNDING AREA IN FREEZING CONDITIONS. THESE 
DAMAGES ARE NOT COVERED UNDER WARRANTY.

DO NOT USE ANTI-FREEZE OR OTHER SOLUTIONS AS A
SUBSTITUTION FOR PROPERLY DRAINING THE ICE MACHINE.

Starting Out ..........................................................3

Installation ............................................................4

Installation: Drain Plumbing .................................5

Water Supply........................................................6

Care of the Unit ....................................................7

Caring for Your Ice Machine.................................8

Things to Remember............................................9

Door Alterations..................................................10

Obtaining Service ...............................................11

Warranty .............................................................12

Troubleshooting.............................................13-16

Service Parts Diagrams & Part Lists ............17-24

Preparing Your Ice Machine for Storage ............25

2

TA B L E   O F   C O N T E N T S

Summary of Contents for 30iM

Page 1: ...MARVEL ICE MACHINE life luxur y mar vel Installation Operation and Maintenance Instructions Clear Ice Models 30iM 3OiM outdoor...

Page 2: ......

Page 3: ...ater Supply 6 Care of the Unit 7 Caring for Your Ice Machine 8 Things to Remember 9 Door Alterations 10 Obtaining Service 11 Warranty 12 Troubleshooting 13 16 Service Parts Diagrams Part Lists 17 24 P...

Page 4: ......

Page 5: ...g or lowering the glides on the bottom of the unit Electrical Connection Check the serial nameplate for the correct power supply Use only the electrical power supply specified on the serial nameplate...

Page 6: ......

Page 7: ...prevent the water line from kinking Operation Your ice machine is unique in forming ice It uses fractional freezing to form a slab of ice that is clear and has less mineral content than the water it...

Page 8: ......

Page 9: ...6 The total cleaning time will end in 49 min utes The cleaning cycle will automatically rinse the evaporator plate and also drain the cleaning solution and rinse water 7 After the cleaning cycle has e...

Page 10: ......

Page 11: ...g the Door You may want to change the side on which the door opens and closes This can be changed by the following steps 1 Remove the door by removing the top hinge pin and angling the door off of the...

Page 12: ......

Page 13: ...ical codes low or high voltages failure to provide necessary maintenance or other unrea sonable use Parts or Service Not Supplied or Designated by Marvel The above warranties also do not apply if The...

Page 14: ......

Page 15: ...unit for proper operation and cube size Restriction in drain lines will cause ice in the bin to melt to a thinner cube If using a gravity drain make certain there are no kinks or restrictions in the d...

Page 16: ......

Page 17: ...unit to an area where temperature is below 90 F Check to see that the ice deflector is in place and secured below the grid cutter You can adjust the bin level sensing tube by simply press ing directl...

Page 18: ......

Page 19: ...242992 6B On Off Clean Switch White 1 41006045 42243097 7A Screw Grille White 4 41005486 42243390 7B Screw Grille Black 4 08205072 42243391 7C Screw Grille Stainless Steel 2 41006774 42246381 42246382...

Page 20: ......

Page 21: ...41005345 42242981 12 Spacer 2 41004366 42242981 13 Screw 2 41005773 42242981 14 Clamp 1 1150003A 42242986 15 Sleeve w thermistor 1 42156278 42246385 16 Screw 2 08204920 42246385 17 Screw 4 08204920 4...

Page 22: ......

Page 23: ...05051 42243194 25 Compressor Assembly 1 41008182 42243194 26 Compressor PTC Starter 1 41008200 42244702 27A Back Panel 1 41009202 42242962 27B Back Panel Outdoor 1 42104901 42245203 28 Power Cord Clam...

Page 24: ......

Page 25: ...1 41008153 42245258 7A Door Assembly Blk complete 1 42034148 42244435 7B Door Assembly S S complete 1 42034150 42244436 7C Door Assembly Wht complete 1 42034149 42244437 8A Screw Blk 4 41007007 42244...