Adjusting Cutting Blades
• DO NOT TOUCH THE SHARPENED
EDGES OF THE CUTTING BIADES.
THE
CUTTING
BLADES
ARE
EXTREMELY SHARP AND DANGER
OUS AT ALL TIMES.
Maintenance Interval
Before operating the
Hedge Trimmer it is neces
sary to check the adjustment of the cutting blades.
Blades that are too loose may vibrate, and will not pro
vide a clean, smooth cut.
Cutting Blades Maintenance
CAUTION-BLADES THAT ARE TOO TIGHT
CAN CAUSE OVERLOADING WHICH MAY
DAMAGE THE EQUIPMENT.
To adjust the cutting blades, refer to the illustrations
and locate the tension screws.
Loosen the tension screw lockouts. Gently tum the ten
sion screws in until snug, then turn the tension screws
back out one-furth to a half While holding the screws in
place, tighten the locknuts. Liberally coat the cutting
blades with light oil. Start the engine and operate the
Hedge Trimmer at full speed fur at least one minute.
Stop the engine and when the blades are motionless, touch
the blades with your hand
Upper Blade
\
(
Lower Blade
Locknut
I /GuideBar
(@
'1
)
'"'
/
Flat Washer
Tension Screw
Locknut
c�-;_.ffe
���
Tension Screw
The blades should be warm, but if they are too hot
to touch, loosen the tension screws another 118
turn.
lubrication
Maintenance Interval
The gearcase and angle drive should be inspect after
each IO to
20
hours of use.
Cutting blades should be lubricated at all times.
Lubrication
The gearcase has a felt wick locataed at the blade
openmg. As the Hedge trimmer is used, the
grease within gearcase becomes very soft.
The reciprocating blades constantly draw small
amounts of grase between the blade contact
surfaces for additional lubrication.
If the gearcase is not lublicated at the re
commened intervals, a gearcase failure will occur
due to a lack of lubrication.
Gearcase failures due to improper maintenance is
not covered by MARUYAMA warranty.
The gearcase and blades should be lubricated after
each 10 hours or use.
NOTE: If the Hedge Trimmer is used under severe
conditions such as high ambient temperatures
(above 75
°
F) or for extended continuous periods
of operation, the gearcase and blades must be
lubricated every 2 hours.
Lubricate the gearcase at the grease fitting with a
good quality#2 litium-base grease. Lubricate the
blades using a light (#10 wt.) oil.
Light Oil (#1 owt.)
\
�
Grease Fitting
for Angle Drive
-�
--
Grease Fitting
for Gearcase