background image

Maestro Wireless

R

 dimmers contain APM features that allow the user to customize their control to meet their 

specific needs. This document serves as a supplement to the instruction sheet. APM features apply to only those 

products with M4 revision software or later while System Configuration Mode (SCM) features apply to those 

products with M6 revision software or later. Please note that the software revision level can be found on the 

outside of the unit and will always start with the letter M. Before entering either mode, it is important to have a 

good understanding of the features included. For a summary of these features and further instructions, see the 

pages corresponding to your product.

Dimmer

B

R

L

F

Key

B

 = Tap Button

R

 = Raise Rocker

L

 = Lower Rocker

F

 =  Front Accessible 

Service Switch (FASS

T

Pull OFF/Push ON

     Note

: The MRF2-3LD and MRF2-3PD products do not have a FASS

T

. In order to cycle power please follow 

the steps below:

1. Unplug the Maestro Wireless

device from the wall outlet.

2. Wait for 3 seconds.

3. Plug the Maestro Wireless

device into a standard wall outlet.

B

R

L

Lamp Dimmer

COOPERSBURG, PA 18036 USA

®

MRF2-3PD

Wireless

®

B

R

L

Plug-In Dimmer

Maestro Wireless

R

 Advanced Programming Mode (APM)

Application Note #370

Revision C 

June 2012

Lutron Technical Support Center 

1.800.523.9466

Summary of Contents for Maestro Wireless MRF2-3LD

Page 1: ... a good understanding of the features included For a summary of these features and further instructions see the pages corresponding to your product Dimmer B R L F Key B Tap Button R Raise Rocker L Lower Rocker F Front Accessible Service Switch FASST Pull OFF Push ON Note The MRF2 3LD and MRF2 3PD products do not have a FASST In order to cycle power please follow the steps below 1 Unplug the Maestr...

Page 2: ...ociating a Radio Powr SavrT occupancy sensor to multiple Maestro WirelessR dimmers switches and set up the system so that only selected loads automatically turn on Other loads would require the user to manually turn on the load When the room is vacant all loads turn off System Configuration Options The user has several options for the configuration of the system Setting the Product Mode The user h...

Page 3: ...ckly flashing LED will move up and down as the preset is changed Your light will get brighter or dimmer to reflect the Locked Preset level as you adjust this feature 2 Press the Tap Button once to return to the Main Menu To select Unlocked Preset 1 Press the Lower Rocker until the bottom LED is quickly flashing Release the lower button and press and hold the lower button again for approximately 3 ...

Page 4: ...er Rocker to adjust the quickly blinking LED to the position that represents the desired fade time 4 Press the Tap Button once to return to the Main Menu Note The default Off Fade Time is 2 5 seconds The fade speed for Raise and Lower operations are not affected by any Off Fade Time modification LED 5 Slowest On Fade Time LED 1 Fastest On Fade Time LED 5 Slowest Off Fade Time LED 1 Fastest Off Fad...

Page 5: ...se Lower Rocker to adjust to the desired brightness High or Low 4 Press the Tap Button once to return to the Main Menu Mode LED 7 Longest Delay 70 Seconds LED 1 Shortest Delay 10 Seconds LED 4 Low Brightness Raise Light Level Lower Light Level LED Position Delayed Fade To Off Time 7 70 seconds 6 60 seconds 5 50 seconds 4 40 seconds 3 30 seconds Default 2 20 seconds 1 10 seconds LED 7 High Brightne...

Page 6: ...l operation The range of this adjustment is limited to the top 3 LEDs When making adjustments to meet lamp life requirements or energy saving it is best to have either a voltmeter or power meter available An alternate approach is to reduce light level to a point where it just meets the maximum light level needs of the space this can be achieved by observation or a light meter 1 While in Main Menu ...

Page 7: ...ing Product Mode Available for Corded Dimmers with M6 software or later only 1 Press the Raise Lower Rocker until LED 3 begins to blink Note LED 7 will also be blinking indicating that the product is in SCM 2 Press the Tap Button once in order to determine the current mode of the product An LED will begin to blink quickly indicating the current mode of the product 3 Press the Raise Lower Rocker to...

Page 8: ... period of five seconds LEDs 1 2 and 3 will begin scrolling indicating that the preset has been set to off 4 Press the Tap Button once to return to the SCM Menu LED Position Vacancy Light Level Preset 4 50 of Load 3 34 of Load 2 17 of Load 1 1 of Load Scrolling 1 2 3 Off Default LED 7 System Configuration Mode LED 4 Highest Vacancy Light Level LED 1 Lowest Vacancy Light Level How to Save Settings ...

Page 9: ...ve the APM Note If you wait 1 minute the dimmer will automatically exit from APM however settings will not be saved Overriding Daylighting Mode Available for products with M6 revision software or later 1 Press the Raise Lower Rocker until LED 6 begins to blink Note LED 7 will also be blinking indicating that the product is in SCM 2 Press the Tap Button once in order to determine the current overri...

Page 10: ...tlet b Press the On Button on the transmitter three times in quick succession and continue holding the button on the third press Please refer to the transmitter s instructions for the appropriate response c Test the transmitter to verify that all of the appropriate devices have been dissociated from the transmitter d Upon confirming success in the previous step push the FASST into the On Position ...

Page 11: ...0 282 6701 EUROPEAN HEADQUARTERS United Kingdom Lutron EA Ltd 6 Sovereign Close London E1W 3JF United Kingdom TEL 44 0 20 7702 0657 FAX 44 0 20 7480 6899 FREEPHONE UK 0800 282 107 Technical Support 44 0 20 7680 4481 lutronlondon lutron com ASIAN HEADQUARTERS Singapore Lutron GL Ltd 15 Hoe Chiang Road 07 03 Tower 15 Singapore 089316 TEL 65 6220 4666 FAX 65 6220 4333 Technical Support 800 120 4491 l...

Reviews: