15
Remove the fuse on the right
side of the Fuse Block
Orient the Voltage Select so
that the required voltage reads
right side up
Insert the correct rated fuse
into the right side of the Fuse
Block.
CAUTION: ALWAYS USE AN APPROPRIATELY
RATED FUSE FOR THE VOLTAGE SELECTED
PRENEZ PRUDENCE: UTILISEZ UN FUSIBLE CORRECTEMENT
CLASSÉ POUR LE VOLTAGE SÉLECTIONNÉ TOUJOURS
100 – 120VAC: 115V
220 – 240VAC: 230V
Incorrect setting will
seriously damage unit
115V: T500 mA – 250V
230V: T500 mA – 250V
Risk of electrical shock
and/or fire
if rated fuse is not used