background image

RUSH SM 650

TM

 User Manual 

Martin™ distributor (see www.martin.com/distributors for 
details) or call the Martin™ 24-hour service hotline on +45 
8740 0000, or in the USA on 1-888-tech-180. 

Respect all locally applicable laws, codes and regulations when 
installing, operating or servicing the smoke machine. 

 

Protection from electric shock 

Do not expose the smoke machine to rain or moisture. 

Disconnect the smoke machine from AC power before carrying 
out any installation or maintenance work and when the smoke 
machine is not in use. 

Ensure that the smoke machine is electrically connected to 
ground (earth). 

Use only a source of AC mains power that complies with local 
building and electrical codes and has both overload and 
ground-fault (earth-fault) protection. 

Socket outlets or external power switches used to supply the 
smoke machine with power must be located near the smoke 
machine and easily accessible so that the smoke machine can 
easily be disconnected from power. 

Replace defective fuses with ones of the specified type and 
rating only. 

Disconnect the smoke machine from power immediately if the 
power plug or any seal, cover, cable, or other component is 
damaged, defective, deformed, wet or showing signs of 
overheating. Do not reapply power until repairs have been 
completed. 

Before using the smoke machine, check that all power 
distribution equipment and cables are in perfect condition and 
rated for the electrical requirements of all connected devices. 

 

Protection from burns and fire 

 

Do not operate the smoke machine if the ambient temperature 
(T

a

) exceeds 40° C (104° F). 

The surface of the product casing can reach up to 50° C 
(122°F) during operation. Avoid contact by persons and 
materials. Allow the smoke machine to cool for at least 10 
minutes before handling. 

Summary of Contents for Rush SM 650

Page 1: ...SM 650 User Manual ...

Page 2: ...nability to use or reliance on the information contained in this manual The Martin logo the RUSH by Martin logo the RUSH by Martin name the Martin name and all other trademarks in this document pertaining to services or products by Martin Professional or its affiliates and subsidiaries are trademarks owned or licensed by Martin Professional or its affiliates or subsidiaries Martin Professional Olo...

Page 3: ... machine on a truss 10 Securing with a safety cable 11 AC power 11 Remote control 12 Wired remote control 12 4 channel wireless remote control and receiver 12 Operation 13 Filling the tank 13 Making smoke 13 Maintenance 14 Cleaning 14 Replacing the primary fuse 14 Replacing the wireless remote control battery 15 Service and repairs 15 Troubleshooting 16 Specifications 17 ...

Page 4: ...s of severe injury or death due to fire and burn hazards electric shock falls and respiratory problems The smoke produced by the machine is hot enough to cause burns or eye injury if the safety precautions below are not followed Install operate and service RUSH by Martin products only as directed in their user manuals or you may create a safety hazard or cause damage that is not covered by product...

Page 5: ...al power switches used to supply the smoke machine with power must be located near the smoke machine and easily accessible so that the smoke machine can easily be disconnected from power Replace defective fuses with ones of the specified type and rating only Disconnect the smoke machine from power immediately if the power plug or any seal cover cable or other component is damaged defective deforme...

Page 6: ...ine Keep combustible materials at least 1 m 40 in away from the machine Do not attempt to bypass thermostatic switches or fuses Replace fuses only with ones of the type and rating specified in this manual for the machine Protection from injury Ensure that any supporting structure and or hardware used can hold at least 10 times the weight of all the devices they support If suspending from a rigging...

Page 7: ...e water and obtain medical advice Block access below the work area and work from a stable platform whenever installing servicing filling or moving the smoke machine In the event of an operating problem stop using the smoke machine immediately and disconnect it from power Do not attempt to use a smoke machine that is obviously damaged Do not modify the smoke machine in any way Refer any service ope...

Page 8: ...less remote control transmitter and receiver a 1 5 m 5 ft power cable local power plug not included on some models and an adjustable mounting bracket Before using the product 1 Read Safety information on page 4 before installing operating or servicing the smoke machine 2 Unpack and ensure that there is no transportation damage before using the smoke machine Do not attempt to operate a damaged smok...

Page 9: ... Smoke machine overview 1 mounting bracket 6 power switch 2 clamp attachment point 7 remote control socket 3 fluid tank 8 remote control socket 4 secondary attachment point 9 AC power socket 5 smoke output nozzle 10 No fluid light ...

Page 10: ...d to a truss or similar rigging structure and tilted up to 45 degrees from horizontal When installing the smoke machine with the mounting bracket hanging vertically down you can use an open type clamp such as a G clamp If installing with the mounting bracket in any other orientation you must use a half coupler clamp see illustration on right that completely encircles the truss chord To clamp the s...

Page 11: ...power switches used to supply the smoke machine with power must be located near the smoke machine and easily accessible so that the smoke machine can easily be disconnected from power The smoke machine can be hard wired to a building electrical installation if you want to install it permanently or a power plug not supplied that is suitable for the local power outlets can be installed on the power ...

Page 12: ...annel wireless remote control and receiver The 4 channel wireless remote control transmitter shown below to left has a range of 30 meters 100 feet It provides individual control of up to 4 smoke machines and simultaneous control of an unlimited number of machines in up to 4 groups The remote control receiver shown above to right connects to a remote control socket on the rear panel It has green re...

Page 13: ... Replace the filler cap and verify that the feed hose touches the bottom of the tank 5 Wipe up any spills or drips Making smoke 1 Fill the fluid tank as described above 2 Connect a remote control or wireless remote control receiver as described on the previous page 3 Connect the smoke machine to AC power and switch it on Allow the machine to heat up for several minutes The machine is ready to use ...

Page 14: ... machine Damage caused by inadequate cleaning or maintenance is not covered by the product warranty Inspect smoke machines within their first 100 hours of operation to see whether cleaning is necessary Check again at frequent intervals This procedure will allow you to assess cleaning requirements in your particular situation If in doubt consult your RUSH by Martin dealer about a suitable maintenan...

Page 15: ...emove the old battery 3 Insert a fresh battery with the negative terminal towards the spring 4 Align the covers and replace the screw to close Service and repairs Do not try to repair the smoke machine by yourself as this may result in damage malfunction and it may potentially void your product warranty The equipment must only be serviced or repaired by an authorized RUSH by Martin service technic...

Page 16: ...form output fluid drips or spits from nozzle or loud noise when firing machine Incompatible smoke fluid Discard fluid and replace with genuine Rush ELX Smoke Fluid No smoke output Machine not ready Allow machine several minutes to heat up Fluid level low Add fluid see page 13 Selected remote control button does not match receiver DIP switch setting Change DIP switch setting see page 12 or press a ...

Page 17: ... kg 9 lbs Dimensions 263 x 283 x 224 mm 10 3 x 11 1 x 8 8 in Performance Max smoke output approx 160 m3 minute Max operating time at full output approx 12 seconds Warm up time approx 4 minutes Control Control options dedicated wired 4 button wireless remote control ...

Page 18: ...um clearance around vents 0 5 m 19 7 in Connections AC power in IEC Wired remote control 5 pin DIN Wireless remote control receiver 5 pin DIN Electrical AC power EU model 220 240 V nominal 50 Hz AC power US model 100 120 V nominal 60 Hz Main fuse EU model 5 AT slow blow Main fuse US model 8 AT slow blow Typical power and current 100 V 60 Hz 717 W 7 17 A 120 V 60 Hz 717 W 6 A 240 V 50 Hz 717 W 3 A ...

Page 19: ...g suspension only P N 91602003 Quick trigger clamp vertical hanging suspension only P N 91602007 Safety wire safe working load 50 kg P N 91604003 Related Items RUSH ELX Smoke fluid 4 x 5 liters P N 97120065 Ordering Information RUSH SM 650 EU P N 90480090 RUSH SM 650 US P N 90480095 Specifications are subject to change without notice For latest product specifications see www martin com Disposing o...