![Martin Rush SM 650 User Manual Download Page 16](http://html1.mh-extra.com/html/martin/rush-sm-650/rush-sm-650_user-manual_1732676016.webp)
RUSH SM 650
TM
User Manual
16
Troubleshooting
This section describes possible problems and provides some suggestions for
easy troubleshooting. Refer the machine to an authorized RUSH by Martin
™
service technician if the suggested remedies do not solve the problem.
Symptom
Potential cause
Remedies
Machine appears
dead
Main fuse blown
Replace fuse (see page 14)
No power at AC cable
inlet
Check power cable and
circuit breaker
Smoke output is
weak
Machine requires
priming
Press and hold the smoke
button until output is strong
Wet, greasy, non-
uniform output, fluid
drips or spits from
nozzle, or loud noise
when firing machine
Incompatible smoke
fluid
Discard fluid and replace
with genuine Rush ELX
™
Smoke Fluid
No smoke output
Machine not ready
Allow machine several
minutes to heat up
Fluid level low
Add fluid (see page 13)
Selected remote control
button does not match
receiver DIP switch
setting
Change DIP switch setting
(see page 12) or press a
different button
Wireless remote control
out of range
Move closer to smoke
machine
Wireless remote control
battery exhausted
Replace battery (see page
15)
”No Fluid” indicator
lit when fluid bottle is
full
Fluid not detected
Check that fluid hose
reaches bottom of tank
Restart machine
Defective circuit
Refer to authorized
technician for service