background image

 

 

  
 

RUSH™ Scanner 1 LED 

 

 

User Manual 

 
 

 

 

Summary of Contents for RUSH Scanner 1 LED

Page 1: ...RUSH Scanner 1 LED User Manual...

Page 2: ...oss occasioned by the use of inability to use or reliance on the information contained in this manual Martin Harman and all other trademarks in this document pertaining to services or products by Mart...

Page 3: ...16 Control data link 18 Tips for reliable data transmission 18 Connecting the DMX data link 18 Fixture setup 20 Using the control menus 20 DMX settings 20 Effects settings 23 Calibration settings 24 S...

Page 4: ...d Warning Risk Group 2 product according to EN 62471 Do not look directly into the beam Do not view the light output with optical instruments or any device that may concentrate the beam This lighting...

Page 5: ...installation or maintenance work and when the fixture is not in use Ensure that the fixture is electrically connected to ground earth Use only a source of AC power that complies with local building a...

Page 6: ...suit the application In the USA and Canada the cables must be UL listed type SJT or equivalent In the EU the cables must be type H05VV F or equivalent Suitable cables with Neutrik PowerCon connectors...

Page 7: ...ertain control menu items are selected To minimize the risk of eye irritation or injury disconnect the fixture from power at all times when the fixture is not in use and provide well lit conditions to...

Page 8: ...ith missing or damaged covers shields or any optical component Block access below the work area and work from a stable platform whenever installing servicing or moving the fixture In the event of an o...

Page 9: ...mounting brackets Before using the product for the first time 1 Read Safety information on page 4 before installing powering operating or servicing the fixture 2 Unpack and ensure that there is no tra...

Page 10: ...t In standalone operation the display shows the number of the selected standalone show 3 Buttons MENU Press to activate the menu Within the menu press to escape and return to the previous level Press...

Page 11: ...ated scene changes in show mode 8 9 10 11 DMX input output sockets For your convenience both 3 pin and 5 pin XLR sockets are provided for DMX input and output throughput Connect suitable DMX data cabl...

Page 12: ...you install the fixture in a location where it may cause injury or damage if it falls secure it as directed in this user manual using a securely anchored safety cable that will hold the fixture if the...

Page 13: ...the clamp when installed In all other installations use a half coupler clamp see illustration on right To clamp the fixture to a truss 1 Check that the rigging structure can support at least 10 times...

Page 14: ...14 RUSH Scanner 1 LED User Manual Rigging with short and long brackets...

Page 15: ...e that the surface and all fasteners used can support at least 10 times the weight of all fixtures and equipment they will support Fasten the fixture securely Do not stand it on a surface or leave it...

Page 16: ...the fixture and easily accessible so that the fixtures can easily be disconnected from power Do not insert or remove live Neutrik PowerCon connectors to apply or cut power as this may cause arcing at...

Page 17: ...n see Accessories on page 42 you can relay mains power from one fixture to another by connecting fixtures to power in a linked daisy chain MAINS OUT throughput socket to MAINS IN input socket Using 14...

Page 18: ...e designed for RS 485 devices standard microphone cable cannot transmit control data reliably over long runs 24 AWG cable is suitable for runs up to 300 meters 1000 ft Heavier gauge cable and or an am...

Page 19: ...utput from the controller to the first fixture s male 3 pin or 5 pin XLR DMX input connector 2 Connect the first fixture s DMX output to the DMX input of the next fixture and continue connecting fixtu...

Page 20: ...ing a change press MENU To exit the control menus completely press and hold MENU DMX settings DMX address The RUSH Scanner 1 LED uses 16 DMX channels The DMX address also known as the start channel is...

Page 21: ...Mode Nine pre programmed standalone shows are available To set the show that the fixture will run in Show Mode 1 Select SHOW MODE and press ENTER 2 Use the DOWN and UP buttons to select a show from 0...

Page 22: ...h the Master fixture When sound activation is running the SOUND status LED on the control panel flashes in sync with the music beat To set sound activation 1 Select SOUND MODE and press ENTER to confi...

Page 23: ...o be linear as DMX value is increased MODE 2 SQUARE LAW light intensity control is finer at low levels and coarser at high levels MODE 3 INVERSE SQUARE LAW light intensity control is coarser at low le...

Page 24: ...ion 1 Power the fixture on if matching multiple fixtures aim them so that their projections are side by side 2 Select DIMMER CALIBRATE and press ENTER 3 Using the DOWN and UP buttons change the value...

Page 25: ...lumination can be turned on or off To adjust the backlight settings 1 Select BACK LIGHT menu and press ENTER 2 Select ON to illuminate the display or OFF for a dark display 3 Press ENTER to confirm yo...

Page 26: ...ixed gobos Gobo wheel 1 shown from front lens side Images will be flipped left right when projected Individual gobos on wheel 1 can be rotated clockwise and counter clockwise and a gobo shake function...

Page 27: ...ture incorporates a prism than can be inserted into the beam providing split effects The prism can be set to an indexed position or rotated clockwise or counter clockwise Strobe effects The strobe eff...

Page 28: ...nadequate cleaning or maintenance is not covered by the product warranty The cleaning of external optical lenses must be carried out periodically to optimize light output Cleaning schedules for lighti...

Page 29: ...the surface hard lift particles off with a soft repeated press Dry with a soft clean lint free cloth or low pressure compressed air Remove stuck particles with an unscented tissue or cotton swab mois...

Page 30: ...us scrolling 0 White 1 14 White Red 15 Red Color 1 16 29 Red Deep Blue 30 Deep Blue Color 2 31 44 Deep Blue Lavender 45 Lavender Color 3 46 59 Lavender Magenta 60 Magenta Color 4 61 74 Magenta Yellow...

Page 31: ...us scrolling 0 White 1 14 White Pink 15 Pink Color 1 16 29 Pink CTO 3200K 30 CTO 3200K Color 2 31 44 CTO 3200K UV Purple 45 UV Purple Color 3 46 59 UV Purple Light Yellow 60 Light Yellow Color 4 61 74...

Page 32: ...Gobo wheel 1 rotating gobos Gobo selection 0 4 Open 5 9 Gobo 1 10 14 Gobo 2 15 19 Gobo 3 20 24 Gobo 4 25 29 Gobo 5 30 34 Gobo 6 Gobo rotation set direction and speed on channel 7 35 39 Gobo 1 40 44 Go...

Page 33: ...fixed gobos Continuous scrolling 0 Open 1 14 Open Gobo1 15 Gobo 1 16 29 Gobo 1 Gobo 2 30 Gobo 2 31 44 Gobo 2 Gobo 3 45 Gobo 3 46 59 Gobo 3 Gobo 4 60 Gobo 4 61 74 Gobo 4 Gobo 5 75 Gobo 5 76 89 Gobo 5 G...

Page 34: ...ockwise rotation fast slow 127 129 Stop 130 253 Counter clockwise rotation slow fast 254 255 Stop 11 0 255 Focus infinity near 12 0 255 Pan 0 170 13 0 255 Pan fine control 14 0 255 Tilt 0 75 15 0 255...

Page 35: ...ntrol panel display 165 194 No function 195 199 Store color wheel 1 calibration 200 204 Store color wheel 2 calibration 205 209 Store gobo wheel 1 wheel calibration 210 214 Store gobo wheel 1 gobo cal...

Page 36: ...ion music trig Off No sound activation Sound Sense 0 100 Microphone sensitivity for sound activation DMX State Show Mode If DMX signal stops fixture enters show mode Blackout If DMX signal stops fixtu...

Page 37: ...ttings No Reset Reset fixture Offset adjustment The Offset menu is used to adjust the home position of the various effects To access the Offset menu 1 Press the MENU button to enter the menu structure...

Page 38: ...e Check all power connections and cables Replace the fixture fuse The fixture does not react to the beat of music Sound activation disabled Sound activation sensitivity too low for music source Ensure...

Page 39: ...all DMX cables and connections to ensure the integrity of the physical link Ensure that the DMX link is terminated Check that all devices on the DMX link use standard DMX polarity Ensure that the fix...

Page 40: ...zed Electronic dimming 0 100 four dimming curve options Pan 170 coarse fine control Tilt 75 coarse fine control Control and Programming Control options DMX standalone synchronized master slave DMX cha...

Page 41: ...f cycle RMS inrush current at 240 VAC 10 A Fuse T 6 3 A Power supply unit Auto ranging electronic switch mode Typical power and current 100 V 60 Hz 1 7 A 170 W PF 0 997 120 V 60 Hz 1 4 A 165 W PF 0 99...

Page 42: ...erCon connectors 2 25 m 7 4 ft P N 11541510 Power relay cable 14 AWG SJT 1 5 mm2 H05VV F with PowerCon connectors 3 25 m 10 7 ft P N 11541511 Power connectors Neutrik PowerCon NAC3FCA power input conn...

Page 43: ...where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of Martin products Phot...

Page 44: ......

Page 45: ......

Page 46: ......

Page 47: ......

Page 48: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...

Reviews: