background image

 Basic 

service 

19

 

Basic service 

 

Before servicing the Magnum 2500HZ, read and observe all the precautions 

listed in “Safety information” on page 3. Any service not described in this 
section must be carried out by a Martin service technician. 

Cleani ng 

Excessive dust, smoke fluid, and dirt buildup will degrade performance and 

cause overheating and damage to the machine that is not covered by the 
product warranty. To maintain adequate cooling, dust must be cleaned from the 
outer casing and air vents of the machine periodically. 

 

 
Isolate the machine from power and allow to cool completely before cleaning. 

The haze output nozzle remains hot for up to 10 hours after use. 

 

 

Remove dust from the air vents with a soft brush, cotton swab, vacuum, 

or compressed air. 

 

Clean smoke fluid residues from the fog output of the machine using a 

damp cloth. 

 

Clean the outer casing with a damp cloth only. 

 
 

Fus e replacement 

The main fuse for the Magnum 2500HZ is located on the electronics board 
inside the unit.  
 

 

DANGER! Disconnect the power supply before removing any covers. Live 
parts inside! 

 
To replace the fuse, disconnect the power cord from the supply, unscrew the 
screws holding the top cover of the unit and remove the cover. The electronics 
board is located at the back of the unit near the remote control sockets.  
 

Remove the fuse holder cover and pull out the fuse. Remove the spent fuse and 
replace with one of exactly the same size and rating. The fuse type is indicated 
below. Contact Martin Service if the fuse blows repeatedly. 
F1 
 

120V = 10AT 

 

230V = 6.3AT 

F2 
 

120V = 3.15AT 

 

230V = 3.15AT 

 

 

Summary of Contents for Magnum 2500Hz

Page 1: ...Magnum 2500HZ user manual P N 35010030D...

Page 2: ...view 12 Continuous haze 12 Setting the Automatic Timer 12 Setting the one shot timer 13 Priming the machine after fluid out 14 What the status lights mean 15 DMX control 16 Overview 16 Connection 16 D...

Page 3: ...th overload and ground fault protection Before connecting the Magnum 2500HZ to power check that the voltage indicated on the machine s serial label matches your local AC power voltage If your AC power...

Page 4: ...nd air vents and ensure free and unobstructed air flow to and around the machine Keep the machine at least 600mm 24 inches away from combustible and heat sensitive materials Do not operate the machine...

Page 5: ...ions on page 18 or you may cause the release of toxic gases presenting a severe health hazard You will also probably damage the machine Do not create dense smoke in confined or poorly ventilated areas...

Page 6: ...Magnum range is all about state of the art technology high quality and ruggedness Congratulations on your purchase of the Magnum 2500HZ from Martin Details of the full range of Martin products are av...

Page 7: ...luid level gauge Warning high temperature vapour and surfaces Hinged door to fluid compartment DMX address selection switches Remote machine link sockets Main power switch Power inlet plug DMX input p...

Page 8: ...achine The power requirements are 4 15A at 230V EU or 8A at 120V US Connect the remote control to the REMOTE IN connector on the rear panel Turn on the power switch The red Heat indicator on the remot...

Page 9: ...he power cable DANGER Make sure the power plug is correctly rated For EU 230V use fit a plug rated 6 amp minimum US 120V models must be fitted with a plug rated 10 amp minimum When installing the plug...

Page 10: ...ect the machine to the DMX line see page 16 Connect the remote to the REMOTE IN socket on the back panel If you are operating several machines using the machine to machine link function connect up the...

Page 11: ...18 the machine is electrically grounded earthed the AC power distribution circuits and lines are adequately rated for the current load Turning on the power Turn on the main power switch located next...

Page 12: ...r mode will run automatically otherwise continuous mode will be enabled and the machine will produce haze until the button is pressed again The green timer LED will light when in continuous run mode S...

Page 13: ...ing the On time To find out what the current time settings are press TIMER SET then rotate the knob slowly until the ON light begins to flash very rapidly The knob is now set to the current run on tim...

Page 14: ...turn the knob back to the required output level and release the FOG button During PRIME mode the machine will prime for 10seconds if any airlock is still visible on the fluid line prime machine again...

Page 15: ...e Haze output level may be reduced while heating ready Machine has finished heating and is at full operating temperature If the ready LED is flashing refer to the following code table Single pulse Cal...

Page 16: ...gnum 2500HZ operates from a single DMX channel which gives proportional control of haze density from 0 100 DMX Level function 0 29 No haze 30 255 Haze at variable density 30 minimum 255 maximum When t...

Page 17: ...458 490 1 1 0 1 0 11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491 0 0 1 1 0 12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 33...

Page 18: ...fely only on the specific haze fluids it is designed for Use ONLY the Martin Jem haze fluids designated in this manual NEVER use any other type of fluid or toxic gas may be produced You will probably...

Page 19: ...m the air vents with a soft brush cotton swab vacuum or compressed air Clean smoke fluid residues from the fog output of the machine using a damp cloth Clean the outer casing with a damp cloth only Fu...

Page 20: ...ne is expected to be out of use for more than 7 days you must drain the fluid system To do this follow the following sequence of operations Switch on the machine and wait for the operating temperature...

Page 21: ...holding in the blanking plate and remove the plate 2 Locate the DMX interface ribbon cable inside the rear of the unit and plug onto the connector on the DMX interface circuit board PL5 3 If you canno...

Page 22: ...by pressing the FOG TIMER ENGAGE button briefly DMX address setting incorrect Change DMX address page 13 Machine can be fired from the remote control but not by DMX controller Poor connection in DMX l...

Page 23: ...ptional accessory 3 pin XLR Remote machine link RJ45 x2 AC power input IEC plug Electrical AC voltage 120V 230V 50 60Hz Main fuse 120V US version 10AT Main fuse 230V EU version 6 3AT Pump fuse 230V 12...

Page 24: ...tor US Model 2m 6 5ft US power cable 18AWG with US male connector UL approved 1 x fluid container empty Accessories DMX decoder module P N 91612011 Ordering information Martin Magnum 2500HZ 120V P N 9...

Page 25: ...Notes 25 Notes...

Page 26: ...26 Notes...

Page 27: ...27...

Page 28: ...Martin Professional A S Olof Palmes All 18 DK 8200 Aarhus N Phone 45 87 40 00 00 Internet www martin com...

Reviews: