32
MAC 401 Dual™ user manual
Dual head module operation
When you install a second head module on the rear of the head and select
DUAL
in the
HEAD
menu,
you have two menus available to you in the control panel:
FRNT
or
REAR
.
• If the
FRNT
menu is selected, all the commands you enter are applied to the fixture and the front head
module.
• If the
REAR
menu is selected, all the commands you enter are applied to the fixture and the rear head
module. Note that the
PERS
,
FACT
,
DMXL
and
SERV
menus are only available in the
REAR
menu.
FRNT MENU
Menu
Item
Options
Notes (Default settings in bold print)
ADDR
1
– XXX
DMX address (default address = 1). The DMX address range is limited
so that the fixture will always have enough DMX channels in the 512
available.
DMX
PSET
RGBX
RGB mode with dynamic effects
HSX
HSV mode with dynamic effects
RGB
RGB mode without dynamic effects
HS
HSV mode without dynamic effects
PGRP
1
Individual control of 4 pixels (segments)
2H
Control of pixels in 2 groups of 2 pixels, horizontal split
2V
Control of pixels in 2 groups of 2 pixels, vertical split
All
All pixels controlled as one group
PINV
OFF
Disable pixel inversion
ON
Pixel inversion: pixels swapped left to right and top to bottom
INFO
VERS
MAIN
CPU firmware version in main processor
HEAD
CPU firmware version in head processor front module / rear module (if
installed)
pOHR
RSET
Hours of operation since counter reset (to reset counter, display counter
and press [Up] for 5 secs.)
TOTL
Total hours of operation since manufacture
MTMP
CURR
Display current main PCB temperature
MSR
Display highest main PCB temperature since last reset
MR
Display highest main PCB temperature since manufacture
DTMP
CURR
Display current average driver PCB temperature
MSR
Display highest driver PCB temperature since last reset
MR
Display highest driver PCB temperature since manufacture
PTMP
CURR
Display current average pixel PCB temperature
MSR
Display highest pixel PCB temperature since last reset
MR
Display highest pixel PCB temperature since manufacture
AIRF
TOTL
Current elapsed time in hours since the air filter was cleaned or
changed. Display the counter and press the up button for five seconds
to reset it.This counter must be reset manually when the air filter is
cleaned.
STTM
Set duration of time alert to be issued after 100-9999 hours have
passed on the
TOTL
counter, to remind you to clean it, particularly the
air filter. The alert appears as long as the value of the
TOTL
counter
is higher than the threshold set here.
SNUM
RDM
Display fixture’s RDM ID
SNUM
Display fixture’s serial number
Table 5: Control menu: dual head module operation, FRNT menu