background image

 36

MAC 401™ user manual

Onboard control menus

Single head module operation

When only one module is installed on the head, the 

HEAD

 menu is automatically set to 

SNGL

. The MAC 

401 automatically detects whether an RGB Zoom or CT Zoom module is installed and adjusts the control 
menu accordingly. The following control menus are available:

Menu

Item

Options

Notes (Default settings in bold print)

ADDR

 – XXX

DMX address (default address = 1). The DMX address range is limited 
so that the fixture will always have enough DMX channels in the 512 
available.

DMX

PSET

(fixture auto-
detects which 
module is 
installed and 
displays either 
RGB/HS

1

 or 

CT

2

 menu 

items)

RAWX

Non-calibrated RGB mode with dynamic effects

1

RGBX

Calibrated RGB mode with dynamic effects

1

HSX

HSV mode with dynamic effects

1

RAW

Non-calibrated RGB mode without dynamic effects

1

RGB

Calibrated RGB mode without dynamic effects

1

HS

HSV mode without dynamic effects

1

CTX

CT mode with dynamic effects

2

CT

CT mode without dynamic effects

2

PGRP

1

Individual control of 4 pixels (segments)

2H

Control of pixels in 2 groups of 2 pixels, horizontal split

2V

Control of pixels in 2 groups of 2 pixels, vertical split

All

All pixels controlled as one group

PINV

OFF

Disable pixel inversion

ON

Pixel inversion: pixels swapped left to right and top to bottom

PERS

PTST

PTSP

Pan and tilt speed normal / fast

SWAP

Swap pan and tilt (pan commands move tilt and vice versa) - off / on

PINV

Pan inversion (reverse direction pan control) - off / on

TINV

Tilt inversion (reverse direction tilt control) - off / on

FANS

REG

Cooling fan speed thermostatically regulated

FULL

Max. cooling fan speed

SLNT

Silent mode. When Silent mode is selected the head fan will turn off. 
The base fan will still run. Values allowed for RGB or HSV (no matter 
what operating mode) will be limited to prevent the fixture from 
producing too much heat. If the LEDs get too hot the fans will revert to 
Regulated mode. When the LEDs are cool enough the fans shift back to 
Silent mode. The color wheel channel will have lower intensity in Silent 
mode.

DIM

LIN

Linear dimming curve

SQR

Square law dimming curve

ISQR

Inverse square law dimming curve

SCUR

S-curve dimming curve

DRES

OFF

Disable reset via DMX

ON

Enable reset via DMX

DISP

ON

Display is permanently on

2MN

Display switches off and goes into Sleep mode if controls have not 
been pressed for 2 minutes.

5MN

Display switches off and goes into Sleep mode if controls have not been 
pressed for 5 minutes

10MN

Display switches off and goes into Sleep mode if controls have not been 
pressed for 10 minutes

DINT

0-100

Display intensity. Default = 100%

ERRM

NORM

Display errors at 100% intensity (regardless of 

DINT

 setting) and 

illuminate the service light.

SLNT

Silent error mode. The error message does not appear in the display, 
but the service lamp is illuminated

CTC

(RGB Zoom 
module only)

WITH

Sending a value on a CTC channel adjusts the temperature of 
whatever color is currently being displayed on segment or fixture

INDP

Sending a value on a CTC channel overrides any color being displayed. 
Fixture or segment switches to white with variable color temperature

Table 6: Control menu: single head module operation

Summary of Contents for MAC 401 CT Zoom

Page 1: ...MAC 401 Dual MAC 401 CT Zoom user manual TM TM...

Page 2: ...sioned by the use of inability to use or reliance on the information contained in this manual The Martin logo the Martin name and all other trademarks in this document pertaining to services or produc...

Page 3: ...AC power before removing or installing any cover or part including fuses and when not in use Always ground earth the fixture electrically Use only a source of AC power that complies with local buildin...

Page 4: ...hat may concentrate the light output Ensure that persons are not looking at the LEDs from within 1 meter 3 feet 4 inches when the product lights up suddenly This can happen when power is applied when...

Page 5: ...ttings 13 Pixel grouping 13 DMX setup 13 Tailoring performance 16 Effects 18 MAC 401 all models 18 MAC 401 Dual RGB Zoom LED module 18 MAC 401 CT Zoom CT Zoom LED module 19 Service and maintenance 20...

Page 6: ...n Professional products please visit the Martin website at http www martin com Comments or suggestions regarding this document may be e mailed to service martin dk or posted to Technical Documentation...

Page 7: ...e 1 Connections panel overview A B C D E F G A AC mains power input Neutrik PowerCon B Fuseholder mains fuse 1 C Fuseholder mains fuse 2 D Ethernet 1 RJ 45 for future use E Ethernet 2 RJ 45 for future...

Page 8: ...label Power cable and plugs The fixture must be connected to AC power using three conductor cable that is rated 20 A minimum 12 AWG or 2 5 mm2 with a diameter of 5 15 mm 0 2 0 6 in The cable jacket m...

Page 9: ...8 in of the cable s outer jacket 4 Strip 8 mm 1 3 in from the end of each of the wires 5 Insert each of the wire ends into the appropriate terminal see Table 1 above and fasten the clamping device us...

Page 10: ...rol data reliably over long runs 24 AWG cable is suitable for runs up to 300 meters 1000 ft Heavier gauge cable and or an amplifier is recommended for longer runs To split the link into branches use a...

Page 11: ...hored safety cable to the safety cable attachment point see Figure 2 if the fixture is to be placed above ground level in any location where it may fall and cause injury or damage Mounting the fixture...

Page 12: ...essed and held for a few seconds to enter the Service menu SERV Control menu shortcuts Hold Menu and press Up Resets fixture Hold Menu and Enter during fixture reset Freezes pan and tilt Hold Up and p...

Page 13: ...ule installed and makes the correct DMX protocol available The module can be controlled using DMX protocol RGB Zoom module on page 25 or DMX protocol CT Zoom module on page 31 depending on which type...

Page 14: ...lor temperature control is available in all six modes CT Zoom module control modes If a CT Zoom LED module is installed it can be set to two DMX control modes in the DMX PSET submenu CTX Warm white co...

Page 15: ...zontally split LED groups 17 12 HS 2V HSV no dynamic effects individual control of 2 vertically split LED groups 17 12 HS All HSV no dynamic effects collective control of all LEDs 13 8 RGBX 1 RGB dyna...

Page 16: ...ll normal situations and ensure excellent service lifetimes for all components The FULL setting maximizes cooling and reduces the operating temperature of the components in the head It is recommended...

Page 17: ...law curve and an S curve that gives finer control at low and high intensities and coarser control at medium intensities see Figure 6 Display settings The DISP submenu can be used to adjust the length...

Page 18: ...are pre programmed macros that give quick access to a variety of effects from the DMX controller without the need for complex programming Effect crossfade times for the change from one segment to the...

Page 19: ...er to white light with variable color temperature CTC control is calibrated at the factory It works in RGB HSV and RAW modes but in RAW mode it is uncalibrated Color wheel effect The electronic color...

Page 20: ...lor and overall brightness over many thousands of hours of use The extent of wear and tear depends heavily on operating conditions and environment so it is impossible to specify precisely whether and...

Page 21: ...the INFO AIRF TOTL control menu reset the counter for elapsed time in hours since the fixture was cleaned to 0 by displaying the counter and pressing and holding the up button for five seconds Removin...

Page 22: ...nd control panel are unusable because the software has become corrupted carry out a boot mode upload see below Boot mode upload Carry out a boot mode upload only if the fixture software is totally cor...

Page 23: ...and the maximum temperature reached since manufacture Lubrication In general the MAC 401 does not require lubrication However depending on use conditions the moving parts in the head and zoom mechani...

Page 24: ...Pixel temperature sensor error YTCO Yoke temperature sensor cutoff The temperature has exceeded the allowed maximum and the LEDs have been switched off DPER Display programming error Reset fixture Con...

Page 25: ...otocol RGB Zoom module RAW RGB HS RAWX RGBX HSX DMX Value Percent Function Snap fade Default DMX value 1 1 0 19 20 49 50 64 65 69 70 84 85 89 90 104 105 109 110 124 125 129 130 144 145 149 150 164 165...

Page 26: ...Magenta Double Segment Chase Effect 14 Yellow Double Segment Chase Effect 15 Yellow Blue Pulse Effect 16 Green Magenta Pulse Effect 17 Red Cyan Pulse Effect 18 Red Green Pulse Effect 19 Red Blue Pulse...

Page 27: ...Effect 19 Red Blue Pulse Effect 20 Red Flip 1 Effect 21 Red Flip 2 Effect 22 Green Flip 1 Effect 23 Green Flip 2 Effect 24 Blue Flip 1 Effect 25 Blue Flip 2 Effect 26 White Flip 1 Effect 27 White Fli...

Page 28: ...ntrol 3 No function Reset Entire fixture1 No function Reset Effects only1 No function Reset Pan Tilt Only1 No function PTSP NORM2 PTSP FAST2 No function Reserved for Future Use No function Fan Mode Fu...

Page 29: ...778 Millennium Gold LEE 135 Deep Golden Amber LEE 164 Flame Red Open white Color wheel rotation effect Clockwise fast slow Color wheel stop freezes at current color Counter clockwise slow fast Open wh...

Page 30: ...ontrolled PGRP is set to 1 The level of control is set using the PGRP option on the control menu on the fixture See Pixel grouping on page 13 The channels control Group C of quadrant split LEDs 18 26...

Page 31: ...220 224 225 229 230 234 235 239 240 244 245 249 250 255 0 7 7 16 17 24 25 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 100 Dynamic effect 1 No Effect Effect 1 White Si...

Page 32: ...e vert seg chase set color temperature using Warm Cold or CT Effect 13 Double opposite chase set color temperature using Warm Cold or CT Effect 14 Reserved for future use Effect 15 Reserved for future...

Page 33: ...to 2H and four other channels control the opposite segment or Group A of 4 quadrant split LED groups PGRP set to 1 and three groups of four other channels control the other three segments 10 18 0 255...

Page 34: ...ot used 20 28 0 255 0 100 Cold white raw CTC channel must be set to a DMX value from 0 9 Zero 100 Fade 0 21 29 0 19 20 255 0 7 8 100 CTC Color Temperature Control calibrated No function Warm and Cold...

Page 35: ...26 255 079 Just Blue 031 093 255 132 Medium Blue 022 161 255 200 Double CT Blue 255 182 200 161 State Blue 255 221 183 201 Full CT Blue 255 135 075 202 Half CT Blue 255 118 045 117 Steel Blue 255 165...

Page 36: ...Tilt inversion reverse direction tilt control off on FANS REG Cooling fan speed thermostatically regulated FULL Max cooling fan speed SLNT Silent mode When Silent mode is selected the head fan will tu...

Page 37: ...e Default value 0999 SNUM RDM Display fixture s RDM ID SNUM Display fixture s serial number MAN RST Reset fixture Press Enter to confirm ALL 0 255 All LEDs intensity 0 100 RED or WARM 0 255 Red if RGB...

Page 38: ...fects1 RAW Non calibrated RGB mode without dynamic effects1 RGB Calibrated RGB mode without dynamic effects1 HS HSV mode without dynamic effects1 CTX CT mode with dynamic effects2 CT CT mode without d...

Page 39: ...rear of head default address 1 The DMX address range is limited so that the fixture will always have enough DMX channels in the 512 available PSET fixture auto detects which module is installed and d...

Page 40: ...lt PAN 0 255 Pan full left pan full right TEST TALL Test LEDs zoom and pan tilt movement T FX Test LEDs and zoom only TP T Test pan tilt movement only TDIS Light all segments in onboard display panel...

Page 41: ...of packets received with errors live STRT Decimal value of the DMX start code live FRNT SHUT FIXT SET 0 255 DMX value received on each channel front module REAR SHUT FIXT SET 0 255 DMX value received...

Page 42: ...hite if CT module installed Intensity 0 50 100 ZOOM Zoom 0 50 100 REAR applies to rear module only RED Red if RGB module installed Warm white if CT module installed intensity 0 50 100 GRN1 Green 1 if...

Page 43: ...Check fixture is set to correct DMX mode One of the fixtures is defective and is disturbing data transmission on the link Unplug XLR in and out connectors and connect them directly together to bypass...

Page 44: ...0 2000 K Electronic color wheel effect 33 LEE referenced colors plus white variable speed color wheel rotation effect and random color CTC Zoom module MAC 401 CT Zoom Warm white 0 100 Cool white 0 100...

Page 45: ...dules installed 100 V 50 Hz 770 W 7 8 A PF 0 996 100 V 60 Hz 765 W 7 8 A PF 0 997 110 V 60 Hz 755 W 7 0 A PF 0 995 120 V 60 Hz 749 W 6 3 A PF 0 993 208 V 60 Hz 732 W 3 6 A PF 0 980 230 V 50 Hz 731 W 3...

Page 46: ...d 5 pin male XLR to 5 pin female XLR IEC UL CL 20 m P N 91611246 Spare parts 10 AT mains fuse P N 05021029 Replacement head air filter P N 62407156 Related items Martin Universal USB DMX Interface Dev...

Page 47: ......

Page 48: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...