Onboard control menus
39
FRNT
(continued)
INFO
(continued)
AIRF
TOTL
Current elapsed time in hours since the air filter was cleaned or
changed. Display the counter and press the up button for five seconds
to reset it.This counter must be reset manually when the air filter is
cleaned.
STTM
Set duration of time alert to be issued after 100-9999 hours have
passed on the
TOTL
counter to remind you to clean it, particularly the
air filter. The alert appears as long as the value of the
TOTL
counter is
higher than the threshold set here. Default value = 0999
SNUM
RDM
Display fixture’s RDM ID (this will be the same in the
REAR
menu)
SNUM
Display fixture’s serial number (this will be the same in the
REAR
menu)
MAN
RST
Reset fixture. Press [Enter] to confirm
ALL
0
–
255
All LEDs, intensity 0 - 100%
RED
or
WARM
0
–
255
Red if RGB module installed, Warm white if CT module installed,
intensity 0 - 100%
GRN1
0
–
255
Green 1 if RGB module installed, intensity 0 - 100%
Not displayed if CT module installed
GRN2
0
–
255
Green 2 if RGB module installed, intensity 0 - 100%
Not displayed if CT module installed
BLUE
or
COLD
0
–
255
Blue if RGB module installed, Cold white if CT module installed,
intensity 0 - 100%
ZOOM
0
–
255
Zoom full wide
→
zoom full narrow (Hypermode)
TILT
0
–
255
Full tilt
→
full opposite tilt
PAN
0
–
255
Pan full left
→
pan full right
TEST
TALL
Test LEDs, zoom and pan/tilt movement
T-FX
Test LEDs and zoom only
TP-T
Test pan/tilt movement only
TDIS
Light all segments in onboard display panel for 5 secs.
REAR
ADDR
1
– XXX
DMX address of module on rear of head (default address = 1). The
DMX address range is limited so that the fixture will always have
enough DMX channels in the 512 available.
PSET
(fixture
auto-
detects
which
module is
installed
and
displays
either
RGB/HS
1
or CT
2
menu
items)
RAWX
Non-calibrated RGB mode with dynamic effects
1
RGBX
Calibrated RGB mode with dynamic effects
1
HSX
HSV mode with dynamic effects
1
RAW
Non-calibrated RGB mode without dynamic effects
1
RGB
Calibrated RGB mode without dynamic effects
1
HS
HSV mode without dynamic effects
1
CTX
CT mode with dynamic effects
2
CT
CT mode without dynamic effects
2
PGRP
1
Individual control of 4 pixels (segments)
2H
Control of pixels in 2 groups of 2 pixels, horizontal split
2V
Control of pixels in 2 groups of 2 pixels, vertical split
All
All pixels controlled as one group
PINV
OFF
Disable pixel inversion
ON
Pixel inversion: pixels swapped left to right and top to bottom
INFO
VERS
MAIN
CPU firmware version in main processor
HEAD
FRNT
= CPU firmware version in head processor front module
REAR
= CPU firmware version in head processor rear module (shows
N/A
if rear module not installed)
POHR
RSET
Hours of operation since counter reset (to reset counter, display counter
and press [Up] for 5 secs.)
TOTL
Total hours of operation since manufacture
MTMP
CURR
Display current main PCB temperature
MSR
Display highest main PCB temperature since last reset
MR
Display highest main PCB temperature since manufacture
DTMP
CURR
Display current average driver PCB temperature
MSR
Display highest driver PCB temperature since last reset
MR
Display highest driver PCB temperature since manufacture
Menu
Item
Item
Options
Notes (Default settings in bold print)
Table 7: Control menu: dual head module operation