Onboard control menus
37
FACT
FACT
LOAD
Return all settings (except calibrations) to factory defaults
NB: can take up to 2 minutes to complete!
CUS1,
CUS2,
CUS3
LOAD
Load custom configuration
SAVE
Save current custom configuration
INFO
VERS
MAIN
CPU firmware version in main processor
HEAD
CPU firmware version in head processor front module (shows
N/A
if
rear module not installed)
POHR
RSET
Hours of operation since counter reset (to reset counter, display counter
and press [Up] for 5 secs.)
TOTL
Total hours of operation since manufacture
MTMP
CURR
Display current main PCB temperature
MSR
Display highest main PCB temperature since last reset
MR
Display highest main PCB temperature since manufacture
DTMP
CURR
Display current average driver PCB temperature
MSR
Display highest driver PCB temperature since last reset
MR
Display highest driver PCB temperature since manufacture
PTMP
CURR
Display current average pixel PCB temperature
MSR
Display highest pixel PCB temperature since last reset
MR
Display highest pixel PCB temperature since manufacture
AIRF
TOTL
Current elapsed time in hours since the air filter was cleaned or
changed. Display the counter and press the up button for five seconds
to reset it. This counter must be reset manually when the air filter is
cleaned.
STTM
Set duration of time alert to be issued after 100-9999 hours have
passed on the
TOTL
counter to remind you to clean it, particularly the
air filter. The alert appears as long as the value of the
TOTL
counter is
higher than the threshold set here. Default value = 0999
SNUM
RDM
Display fixture’s RDM ID
SNUM
Display fixture’s serial number
MAN
RST
Reset fixture. Press [Enter] to confirm
ALL
0
–
255
All LEDs, intensity 0 - 100%
RED
or
WARM
0
–
255
Red if RGB module installed, Warm white if CT module installed,
intensity 0 - 100%
GRN1
0
–
255
Green 1 if RGB module installed, intensity 0 - 100%
Not displayed if CT module installed
GRN2
0
–
255
Green 2 if RGB module installed, intensity 0 - 100%
Not displayed if CT module installed
BLUE
or
COLD
0
–
255
Blue if RGB module installed, Cold white if CT module installed,
intensity 0 - 100%
ZOOM
0
–
255
Zoom full wide
→
zoom full narrow (Hypermode)
PAN
0
–
255
Pan full left
→
pan full right
TILT
0
–
255
Full tilt
→
full opposite tilt
TEST
TALL
Test LEDs, zoom and pan/tilt movement
T-FX
Test LEDs and zoom only
TP-T
Test pan/tilt movement only
TDIS
Light all segments in onboard display panel for 5 secs.
DMXL
RATE
DMX transmission speed, live, in packets per second
QUAL
Percent of packets received with errors, live
STRT
Decimal value of the DMX start code, live
SHUT -
FIXT SET
0
–
255
DMX value received on each channel
SERV
To access
this menu,
hold
[Enter]
pressed for
a few
seconds
PTFB
ON
Enable pan/tilt position feedback/correction system
OFF
Disable pan/tilt feedback for servicing (this setting is not saved when
fixture is reset)
ADJ
Effects adjustment menu (for service use: for full details of this menu,
see “Adjustment submenu” on page 42)
CAL
(OF = offset)
P OF
Pan calibration 0- 255
T OF
Tilt calibration 0 - 255
DOF
SURE
Load factory effects calibration settings
PCBT
SURE
PCB test: for service use only
UPLD
SURE
Manually set fixture to receive software upload
Menu
Item
Options
Notes (Default settings in bold print)
Table 6: Control menu: single head module operation