F1
Undefined
Part of MIDI time code
F2 yy zz
Song position
pointer
yy=least significant, zz=most significant
F3 yy
Song Select
yy=song number
F4 yy
MLD tempo
control
yy=tempo deviation ($00 to $7F, $40 is no change,
smaller than $40 slows tempo down, larger than $40
speeds tempo up)
F5
Undefined
F6
Tune request
F7
EOX flag
End of system exclusive flag
F8
Timing clock
F9
Undefined
Part of MIDI time code
FA
Start
FB
Continue
FC
Stop
FD
Undefined
FG
Active Sensing
FF
System Reset
IMPORTANT NOTE: MIDI “running status” is not supported, all MIDI commands must
be prefixed with their command byte. Running status is a way of shortening midi
messages sent consecutively; for instance with running status one could define two
note-on events on channel 1 as follows: $90, $40, $7F, $50, $7F rather than the way it
actually has to be done in the MLD, which is $90, $40, $7F, $90, $50, $7F.
MLD manual 1.1