Installation and setting up
11
Setting up
Fill the fluid tank only with Martin R365 Haze Fluid™ (see page 20).
Connect the gas line from the CO
2
cylinder using the push fit connector on the
rear panel. Connect the regulator to the cylinder, ensuring plastic washer is in
place, and tighten using a suitable spanner (see picture below). Fully turn on the
gas valve at the cylinder. If using a variable regulator, set to 30PSI or 2Bar. No
gas adjustment is required to vary the output of the machine.
If DMX control is being used, connect the machine to the DMX line (see page
18).
If the Jem Digital Remote is being used (optional accessory), connect the remote
to the Remote socket (see page 17).
The haze deflector flap on the front of the machine can be positioned in either
the raised position so the haze goes up into the air, or in the lowered position to
reduce air turbulence.
Final ch ecks
Before applying power to the haze machine, verify the following:
•
the machine is safely located or installed and meets the location
requirements stated on page 10
•
the operator is familiar with, and able to comply with, the requirements
for safe operation listed on page 4.
•
the haze fluid is one of the genuine Martin fluids listed under “Haze fluid
options” on page 20.
•
the machine is electrically grounded (earthed)
•
the AC power distribution circuits and lines are adequately rated for the
current load
Tur ni ng on th e power
Turn on the main power switch located next to the power inlet. The display will
show
, then after about 5-6 minutes the display will show
and the
machine is ready to produce haze.