background image

Troubleshooting

23

T

ROUBLESHOOTING

A

* To test the data link with an ohm meter, disconnect the link from the controller
and measure the resistance across pins 2 and 3 of the XLR male plug. The reading
should be around 120 ohms. Readings from 400 - 20,000 ohms indicate the data
link is not terminated. Infinite resistance indicates a bad connection, broken wire, or
a defective fixture. Very low readings indicate a short circuit in the link or a
defective fixture. 

problem

probable cause(s)

suggested remedy

None of the fixtures 
respond to the controller.

The controller is discon-
nected from the data link.

Connect controller.

Blackout or standby mode 
selected.

Press blackout button.

Some fixtures do not 
respond, respond errati-
cally, or continuously reset.

Bad data link connection.

Check data link connec-
tions/cables and correct 
accordingly.* 

DMX signal polarity 
reversed.

Swap pins 2 and 3. See 
section 2.

DMX signal reflection. 

Insert termination plug in 
the last light on the link.

Incorrect addressing of fix-
tures.

Check addresses. 

Fixtures not on.

Turn on fixtures.

Fixtures do not execute pro-
gramming on one or more 
channels. 

Fader control is overriding 
programming. 

Deactivate the FIXTURE 
button. 

No light from some or all fix-
tures.

The scenes do not contain 
‘Lamp On’ instructions for 
fixtures with remote lamp 
on/off.

Make sure the “Lamp On” 
command is saved in at 
least one scene.

One or more bank names 
have disappeared

Bank name or names have 
been deleted by going into 
EDIT mode, selecting 
SHOW and then pressing 
ENTER without giving a 
new name to the bank.

Rename banks (see “Giving 
names to banks” on page 
15)

Summary of Contents for Freekie

Page 1: ...Freekie user manual...

Page 2: ...ssional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from Martin Professional A S Denmark Printed in Denmark P N 3...

Page 3: ...mming shows 16 Programming a show 16 Playback 18 Running a show 18 Execution using programmed scene times 18 Music trigger execution 18 MIDI triggering 18 Manual control of individual fixtures during...

Page 4: ......

Page 5: ...For audio controlled shows there is the choice of either external signal input or the Freekie s own internal microphone FEAT URES Controls up to 12 fixtures or fixture groups each with 12 channels 10...

Page 6: ...ure the device is properly grounded Do not operate the device with the cover removed Immediately repair or replace damaged power cords There are no user serviceable parts inside refer all service to a...

Page 7: ...1 amp can be used CONNECTING THE SERIAL LINK About serials links The Freekie sends instructions through a serial data link The link goes from the controller s output to the input of the first lightin...

Page 8: ...re provided on the Freekie 3 Never use a Y connector to split the link If you need to split the serial link into branches use a dedicated splitter amplifier such as the Martin 4 Channel Opto Isolated...

Page 9: ...the same DMX address The Freekie can control the first 12 channels of each fixture or group and can activate smoke and strobe fixtures The Freekie assigns 12 channels to each fixture regardless of ho...

Page 10: ...10 DMX address setting 5 49 6 61 7 73 8 85 9 97 10 109 11 121 12 133 Strobe 145 Freekie fixture ID DMX address DIP switch setting...

Page 11: ...l fixtures may use the same address They will receive the same instructions and behave identically Make a note of the fixtures and the fixture ID that they have been assigned to You will need this to...

Page 12: ...t up and any other fixture of the same type using the numbered buttons 1 12 You can select a range of fixtures by pressing and holding the first and last fixture buttons 5 Press ENTER 6 Specify the pa...

Page 13: ...to leave fixture set up mode STROBE SET UP The Freekie can control one or more strobe devices that have a DMX control address of 145 During a show you can activate strobe effects using the STROBE butt...

Page 14: ...or haze using the appropriate faders representing channels 1 12 and then press ENTER 6 Press EDIT to leave fixture set up mode FOLLOW SPOT SET UP The Freekie can use an individual fixture as a follow...

Page 15: ...ter and move on to the next or press DEL to delete a character you have entered 6 Repeat steps 4 and 5 until you have added the new name You can use up to 7 letters or digits 7 Press ENTER once to sav...

Page 16: ...using any one of the numbered buttons 1 12 6 The display shows 7 Press FIXTURE 8 Use the number buttons to select one or multiple fixtures You can select a range of fixtures by pressing and holding t...

Page 17: ...ram the other effects such as color and gobo usage as the macros are not transparent the look of the previous scene is not carried over The macro is not used during the fade but starts during the wait...

Page 18: ...c trigger execution to the beat of the music or MIDI show execution Execution using programmed scene times Shows will run using their programmed scene times when the FADE TIME PITCH fader is in the mi...

Page 19: ...n the first bank Keys 13 24 are used to activate corresponding shows in the second bank Keys 25 36 are used to activate corresponding shows in the third bank From software v 1 2 the bank does not need...

Page 20: ...n page 12 Press BLACKOUT to activate blackout mode Press it again to reset the fixtures to the current scene Blackout does not affect the follow spot fixture if this has been activated see Follow spot...

Page 21: ...page 14 Activate smoke effects by pressing the SMOKE button and holding it as long as required While the SMOKE button is being held the faders can be used to control the first 12 channels of the smok...

Page 22: ...ating the PIN code lock To deactivate the PIN code lock 1 Simultaneously press and hold the SPOT and FINE buttons for 5 seconds 2 Enter the PIN code factory set as 221174 Use the fixture buttons to se...

Page 23: ...pond respond errati cally or continuously reset Bad data link connection Check data link connec tions cables and correct accordingly DMX signal polarity reversed Swap pins 2 and 3 See section 2 DMX si...

Page 24: ...ach containing up to 12 shows Scene capacity per show 10 D M X C A P A C I T Y DMX signal input output DMX512 DMX signal output 168 Channel DMX connector XLR 5 PIN x2 3 PIN x2 T R I G G E R S O U R C...

Reviews: