background image

 Exterior 

Wash

TM

 100 Series User Manual 

11 

 

 

Physical installation 

 

Warning! Read ‘Safety information’ on page 5 before installing the fixture.   

Contact your Martin® supplier for assistance if you have any questions about how to install 
this product safely. 

Fixture location 

Exterior Wash

 100 Series fixtures are intended for outdoor use. With an IP rating of 66, they are dust 

tight and able to withstand powerful water jets, but they are not submersible.  

Observe the following limitations in selecting a location:  

  Do not immerse the fixture in water or any other fluid. 

  Do not install fixtures in a location where flooding may occur. 

  Do not allow water to collect on or near the pressure relief valve. Do not install a fixture with the valve 

membrane horizontal so that water can pool on it. 

  Ensure sufficient drainage to cope with the heaviest rainfall. Make sure that water can drain away 

from the installation area at least as fast as it can enter it. 

  Fixtures require free and unobstructed airflow around them to ensure adequate cooling: do not bury or 

locate in an unventilated space. Allow at least 0.1 m (4 in.) free space around the fixture. 

  Install the fixture at least 0.2 m (8 in.) away from the surface to be illuminated and at least 0.1 m (4 in.) 

away from any combustible materials (wood, paper, etc.). Keep it well away from any flammable 
materials. 

  The fixture can become hot. Restrict public access or locate the fixture so that it cannot accidentally 

be touched. 

Mounting the fixture 

 

Warning! All fasteners used to mount Exterior Wash

 100 Series 

fixtures must be corrosion resistant and strong enough to mount the 
fixture safely.  

A washer must be installed directly under the head of each fastener 
when anchoring the base of the mounting yoke to the installation 
surface. 

The fixture and yoke can be mounted at any angle. The yoke allows the fixture to be manually panned and 
tilted for beam aiming adjustment. 

The fixture and yoke are manufactured in corrosion-resistant anodized aluminum. Avoid mounting the 
fixture in direct contact with other types of metal, as this can cause galvanic corrosion. When fastening to 
a dissimilar metal surface: 

  Use an electrically insulating material (such as dense rubber or plastic) or coating between the 

mounting yoke and the other metal. 

  Use a non-conductive coating such as Delta Seal on fasteners (screws, bolts, washers, etc.) where 

they come into contact with the mounting yoke. 

The fixture’s mounting yoke base must be securely and safely anchored to a stable, static surface, 
pedestal, structural beam or other suitable support. Do not stand the fixture unanchored on a surface or 
leave it where it can be moved or fall over. 

Mounting on a surface 

To anchor the mounting yoke to a wall or other flat surface, use three high-strength corrosion-resistant 
fasteners that are safe for the application and the environment (recommended minimum properties: 
stainless steel A4-70 grade according to ISO 3506 or steel grade 8.8 according to ISO 898-1). Use self-
locking nuts. Install washers under all nuts and bolt heads. Make sure that there is a washer between 
each fastener and the yoke base. Ensure that the surface and all fasteners used can support 10 times the 
weight of all the fixtures and equipment that they will support. 

Summary of Contents for Exterior Wash 100

Page 1: ...Exterior Wash 100 Series User manual...

Page 2: ...the information contained in this document 2013 2018 HARMAN Professional Denmark ApS All rights reserved Martin is a registered trademark of HARMAN Professional Denmark ApS registered in the United S...

Page 3: ...Connecting to power 15 Control data link 17 Connecting the data link 17 Setup 19 Accessing and navigating the control menus 19 DMX settings 19 Programming a standalone show 20 Manual mode 21 Display s...

Page 4: ......

Page 5: ...re hazard or a risk of eye injury if the safety precautions below are not followed Respect all locally applicable laws codes and regulations when installing operating or servicing the fixture If you h...

Page 6: ...ing water pollution temperature and UV resistance Protection from burns and fire Do not operate the fixture if the ambient temperature Ta exceeds 45 C 113 F The surface of the fixture can reach up to...

Page 7: ...them At distances greater than 1 6 m 5 25 ft potential eye and skin injury hazards from the light output are normally prevented by natural aversion reflexes Position the Exterior Wash 100 so that pers...

Page 8: ...to a rigging clamp Do not use safety cables as the primary means of support If the fixture is installed in a location where it may cause injury or damage if it falls provide a secondary attachment su...

Page 9: ...ructures building features and landscaping All models have a built in display for ease of use a wide selection of beam angles and sealed construction suited to permanent outdoor use A discreet optiona...

Page 10: ...or setting up the fixture before it is hard wired to a mains supply install a local power plug not supplied to the end of the supplied power cable 4 Before operating ensure that the voltage and frequ...

Page 11: ...sh 100 Series fixtures must be corrosion resistant and strong enough to mount the fixture safely A washer must be installed directly under the head of each fastener when anchoring the base of the moun...

Page 12: ...with a safety cable or similar secondary attachment that is approved for the weight of the fixture so that the safety cable will hold the fixture if the rigging clamp fails Loop the safety cable thro...

Page 13: ...m angle 110 model Half peak beam angle 100 120 models None 10 7 Narrow 91610145 10 14 12 Medium 91610146 20 22 21 Wide 91610147 40 41 40 Very Wide 91610148 60 61 60 Asymmetric 91610149 10 x 60 14 x 61...

Page 14: ...al snoot for Exterior Wash 100 Series fixtures may be installed with or without a diffuser lens see above To install shut down power to the fixture then align the snoot to fit over the front of the fi...

Page 15: ...is easily accessible and is located close to the fixtures Do not use an external dimming system to supply power to the fixture as this may cause damage to the fixture that is not covered by the produc...

Page 16: ...able for temporary use such as setting up a fixture before installation for example only If you choose to do this install a grounding type earthed plug with integral cable grip that is rated minimum 2...

Page 17: ...the end of each branch by placing a 120 ohm resistor available from Martin P N 04150308 across the data output hot ve and data output cold ve conductors of the last fixture in the chain Avoid creatin...

Page 18: ...r shell as this may cause interference Wires Input pair red tube Output pair black tube Shield Wire color White green Green White brown Brown Black Signal DMX in DMX in DMX out DMX out Common Male XLR...

Page 19: ...green blue and white LEDs Since fixtures are uncalibrated slight differences in color and or intensity between different fixtures may be visible in the light output from multiple fixtures but you can...

Page 20: ...same DMX control mode may share the same address and control channels if identical behavior is desired The DMX address may be set from the control panel or by RDM To set the fixture s DMX address fro...

Page 21: ...s ENTER Display auto turn off The display can be set to stay on or to turn off 1 minute after the last key press To set display behavior 1 Access the control menu and select DISPLAY SETTINGS Press ENT...

Page 22: ...fixtures This means that standalone operation is only possible if no DMX signal is present If you want master slave operation set only the first fixture on the link to MASTER Set all the other fixtur...

Page 23: ...changes 4 Press ENTER White balance In Exterior Wash 100 and 110 models you can modify the white balance of the fixture s output by adjusting the amount of each color used in the mix to give white To...

Page 24: ...t to reduce the risk of unauthorized access to the control menus you can set the fixture to require a user password before the control panel becomes operative Password protection is disabled by defaul...

Page 25: ...mple shown but all Exterior Wash fixtures are similar Setting Effects Speed via RDM The example below shows how you can change the speed at which the fixture changes effects from Slow optimized for sm...

Page 26: ...o not use products that contain solvents abrasives or caustic agents for cleaning as they can cause surface damage to the fixture The aluminum housing and front glass can be cleaned with mild detergen...

Page 27: ...ability to control overall intensity level on DMX channel 1 Output is not calibrated Channel Value Function 1 0 255 Dimmer 0 100 2 0 255 Red 0 100 3 0 255 Green 0 100 4 0 255 Blue 0 100 5 0 255 White...

Page 28: ...and 2 Channel 3 gives color temperature control from warm to cold at maximum output intensity When set to a level above 26 channel 3 overrides channels 1 and 2 Channel Value Function 1 0 255 Warm Whit...

Page 29: ...0 255 Edit Scene Color Exterior Wash 120 1 last scene Cold white 0 255 Individual scene color temperature Warm white 0 255 Fade Time 0 120 secs 3 secs Transition time between scenes Hold Time 0 600 s...

Page 30: ...Dimming behavior see page 22 Square Law Inverse Square Law S Curve Effects speed Fast Optimize effects for speed Slow Optimize effects for smoothness White Balance Exterior Wash 100 and 110 Red 90 10...

Page 31: ...nk defective Check number of DMX channels required by each fixture and check DMX addresses on fixtures and DMX controller Check fixture s DMX MODE setting Inspect connections and cables Correct poor c...

Page 32: ...Receiver RS 485 Firmware update Serial upload via DMX link DMX compliance USITT DMX512 A RDM compliance ANSI ESTA E1 20 Exterior Wash 100 and 110 DMX channels 3 4 or 5 Exterior Wash 120 DMX channels...

Page 33: ...ge Maximum total power consumption 50 W Typical half cycle RMS inrush current at 240 V 50 Hz 9 7 A Typical power and current Exterior Wash 100 100 V 60 Hz 0 5 A 42 W PF 0 99 120 V 60 Hz 0 4 A 42 W PF...

Page 34: ...es wide beam diffuser kit P N 91610147 Exterior Wash 100 Series very wide diffuser kit P N 91610148 Exterior Wash 100 Series asymmetric diffuser kit P N 91610149 Exterior Wash 100 Series glare shield...

Page 35: ...uipment where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of Martin produ...

Page 36: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...

Reviews: