M a x i m u m h e a t o u t p u t
195 V @ 50/60 Hz ...............................................................................................665 BTU/hour
210 V @ 50/60 Hz ...............................................................................................716 BTU/hour
225 V @ 50/60 Hz ...............................................................................................767 BTU/hour
245 V @ 50/60 Hz ...............................................................................................836 BTU/hour
277 V @ 50/60 Hz ...............................................................................................945 BTU/hour
* These measurements have a margin of error of +/- 10%
A C S u p p l y
AC input ..................................................................... 1.8 m (5.9 ft) trailing cable w/o cord cap
Power supply options ........................................................... 195/210/225/245/277 V, 50/60 Hz
Primary fuse ........................................................................................T 3.15 A, high I
2
t, 250 V
Fuse F1.....................................................................................................................T 2A, 250 V
Fuse F2 ....................................................................................................................T 2A, 250 V
M a x i m u m p o w e r a n d c u r r e n t
195 V @ 50/60 Hz .................................................................................................210 W, 1.2 A
210 V @ 50/60 Hz .................................................................................................220 W, 1.1 A
225 V @ 50/60 Hz .................................................................................................200 W, 1.0 A
245 V @ 50/60 Hz .................................................................................................200 W, 0.9 A
277 V @ 50/60 Hz .................................................................................................200 W, 0.8 A
* These measurements have a margin of error of +/- 10%
C o n s t r u c t i o n
Housing ........................................................................................................extruded aluminum
Finish ..................................................................................... anodized, natural aluminum color
Front glass ........................................................................ 6 mm (0.24 in) anti-reflection coated
Mounting bracket ................................................................. 8 mm (0.3 in) anodized aluminum
Housing-to-bracket attachment ............................4 stainless steel M6 bolts, A2 DIN 933, 18.8
Protection factor ................................................................................................................. IP 65
A p p r o v a l s
EU EMC ................EN 55 015, EN 55 103-1, EN 61 547
EU safety .......................... EN 60598-2-3, EN 60598-2-5
US safety ........................................UL 1573, 4th Edition
Canadian safety ................................CSA C22.2 No. 166
Summary of Contents for Exterior 200
Page 1: ...Exterior 200 user manual mar tinar chi tect ura l ...
Page 5: ...5 SECTION 1 GETTING STARTED ...
Page 27: ...General operation 27 SECTION 2 STAND ALONE OPERATION ...
Page 48: ...48 Synchronous triggering during Stand Alone operation ...
Page 49: ...Synchronous triggering during Stand Alone operation 49 SECTION 3 DMX CONTROL ...
Page 53: ...DMX Controller operation 53 SECTION 4 OPTICS ...
Page 57: ...Lens options 57 SECTION 5 SERVICE AND TROUBLESHOOTING ...
Page 65: ...SECTION 6 REFERENCE ...
Page 75: ......