Consult a qualified engineer to determine a suitable anchoring method. The
specific fastening hardware will depend on the installation. In general, use
high quality metric grade 8.8 or better corrosion resistant screws such as
zinc-plated steel, and self-locking nuts or lock-washers to secure the fixture.
Fixture orientation and location
When choosing a location for the fixture, consider that it has an ingress
protection rating of 65. This means that the fixture is totally dust proof and
that it is protected from water ingression to the level that moisture from low-
pressure water jets from any direction cannot get into the product. However,
the product is not designed to withstand:
• High-pressure water jets from any direction
• Immersion in water (or any other fluid)
Do not bury the Exterior 200 or otherwise locate it in an unventilated space.
Install the fixture in a location where it is
• at least 0.5 meters (20 inches) away from the surface to be illuminated,
• at least 1 meter away from any combustible materials, and
• away from accidental public contact.
If the fixture points down, it must be installed with the power section over the
lamp section as shown so that water cannot collect between the lamp
section and the power section.
When the fixture is located above the area to be illuminated, install with
the power section on top.
Summary of Contents for Exterior 200
Page 1: ...Exterior 200 user manual mar tinar chi tect ura l ...
Page 5: ...5 SECTION 1 GETTING STARTED ...
Page 27: ...General operation 27 SECTION 2 STAND ALONE OPERATION ...
Page 48: ...48 Synchronous triggering during Stand Alone operation ...
Page 49: ...Synchronous triggering during Stand Alone operation 49 SECTION 3 DMX CONTROL ...
Page 53: ...DMX Controller operation 53 SECTION 4 OPTICS ...
Page 57: ...Lens options 57 SECTION 5 SERVICE AND TROUBLESHOOTING ...
Page 65: ...SECTION 6 REFERENCE ...
Page 75: ......