General operation
25
General operation
General guidelines
When the Exterior 200 is connected to power it will reset.
For optimum lamp life, turn off lamp power whenever illumination is not
required for extended periods of an hour or more. Fixture power may remain
on when not in use.
When the temperature is expected to fall below freezing, leave the fixture
powered on when not in use to keep the electronics warm. The lamp,
however, may be switched off.
Always allow the lamp to warm up fully before turning it off.
Avoid turning on several lamps at once.
The LEDs and fixture operating
status
Two LEDs on the rear panel display the
fixture status. Normal operation is indicated
by two green LEDs. See Table 4 for other
status messages.
The LEDs flash off for a brief instant at
regular intervals to prevent false readings
when the light sensor samples the light level.
Appearance
Message, LED 1
Message, LED 2
Steady green
Effects OK
Data OK.
Steady red
-
Invalid data/no data
Steady yellow
Upload in progress
Upload in progress
Blink red
Memory error
-
Blink yellow
Reset in progress
Reset in progress
Table 4: LED status messages
LED 1
LED 2
SENSOR
Summary of Contents for Exterior 200
Page 1: ...Exterior 200 user manual mar tinar chi tect ura l ...
Page 5: ...5 SECTION 1 GETTING STARTED ...
Page 27: ...General operation 27 SECTION 2 STAND ALONE OPERATION ...
Page 48: ...48 Synchronous triggering during Stand Alone operation ...
Page 49: ...Synchronous triggering during Stand Alone operation 49 SECTION 3 DMX CONTROL ...
Page 53: ...DMX Controller operation 53 SECTION 4 OPTICS ...
Page 57: ...Lens options 57 SECTION 5 SERVICE AND TROUBLESHOOTING ...
Page 65: ...SECTION 6 REFERENCE ...
Page 75: ......