Martin Engineering M3687-12/17
15
Martin
®
DT2S Reversing Cleaner
Maintenance
NOTE
Maintenance inspection should be performed weekly until a
maintenance schedule can be determined. Certain
applications and/or changing material conditions may require
more frequent maintenance inspections.
DANGER
!
Before installing, servicing, or adjusting the belt cleaner, turn
off and lockout / tagout / blockout / testout all energy sources
to the conveyor and conveyor accessories according to ANSI
standards. Failure to do so could result in serious injury or
death.
Routine
Inspection/
Tension
1. Inspect the condition of the cleaner. Open the inspection door (if fitted)
and observe the condition and action of the blades and cleaner.
2. If necessary, remove any material buildup from the blades or mainframe.
WARNING
!
Do not reach into the chute while the conveyor is running.
3. If necessary, adjust the cleaner tension. Refer to appropriate section for
tensioner used.
4. Make sure all fasteners are tight. Tighten if necessary.
5. Check blades for wear and replace if necessary.
6. Wipe warning labels clean. If labels are not readable, contact Martin
Engineering or a representative for replacements.
DANGER
!
Before installing, servicing, or adjusting the belt cleaner, turn
off and lockout / tagout / blockout / testout all energy sources
to the conveyor and conveyor accessories according to ANSI
standards. Failure to do so could result in serious injury or
death.
Blade Servicing
1. Undo tensioner and visually inspect blades.
a. If blades are clean and not excessively worn, re-tension cleaner.
b. If material buildup is still present or blades are worn excessively,
proceed.
2. When fully retracted, simply remove the retaining pin securing the blade
cartridge to the operator end of the mainframe. Grasp the handle and pull
the blade cartridge off the mainframe and away from the mount bracket.
Completely remove the blade cartridge from the mainframe and place it
in a suitable position for maintenance work to be carried out.
3. Clean and inspect the blades. If blades are excessively worn, replace with
new blades. Remove the blades from the cartridge by removing one of the
Maintenance