Find the address in the table. Read the settings for pins 1 - 5 to the left and read the
settings for pins 6 - 9 above the address. “0” means OFF and “1” means ON. Pin
10 is always OFF for DMX operation.   

DIP switch Setting

0 = OFF

1 = ON

#9

0

0

0

0

0

0

0

0

1

1

1

1

1

1

1

1

#8

0

0

0

0

1

1

1

1

0

0

0

0

1

1

1

1

#7

0

0

1

1

0

0

1

1

0

0

1

1

0

0

1

1

#6

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

#1 #2 #3 #4 #5

0

0

0

0

0

32 64 96 128 160 192 224 256 288 320 352 384 416 448 480

1

0

0

0

0

1

33 65 97 129 161 193 225 257 289 321 353 385 417 449 481

0

1

0

0

0

2

34 66 98 130 162 194 226 258 290 322 354 386 418 450 482

1

1

0

0

0

3

35 67 99 131 163 195 227 259 291 323 355 387 419 451 483

0

0

1

0

0

4

36 68 100 132 164 196 228 260 292 324 356 388 420 452 484

1

0

1

0

0

5

37 69 101 133 165 197 229 261 293 325 357 389 421 453 485

0

1

1

0

0

6

38 70 102 134 166 198 230 262 294 326 358 390 422 454 486

1

1

1

0

0

7

39 71 103 135 167 199 231 263 295 327 359 391 423 455 487

0

0

0

1

0

8

40 72 104 136 168 200 232 264 296 328 360 392 424 456 488

1

0

0

1

0

9

41 73 105 137 169 201 233 265 297 329 361 393 425 457 489

0

1

0

1

0

10 42 74 106 138 170 202 234 266 298 330 362 394 426 458 490

1

1

0

1

0

11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491

0

0

1

1

0

12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492

1

0

1

1

0

13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493

0

1

1

1

0

14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494

1

1

1

1

0

15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495

0

0

0

0

1

16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496

1

0

0

0

1

17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497

0

1

0

0

1

18 50 82 114 146 178 210 242 274 306 338 370 402 434 466 498

1

1

0

0

1

19 51 83 115 147 179 211 243 275 307 339 371 403 435 467 499

0

0

1

0

1

20 52 84 116 148 180 212 244 276 308 340 372 404 436 468 500

1

0

1

0

1

21 53 85 117 149 181 213 245 277 309 341 373 405 437 469 501

0

1

1

0

1

22 54 86 118 150 182 214 246 278 310 342 374 406 438 470 502

1

1

1

0

1

23 55 87 119 151 183 215 247 279 311 343 375 407 439 471 503

0

0

0

1

1

24 56 88 120 152 184 216 248 280 312 344 376 408 440 472 504

1

0

0

1

1

25 57 89 121 153 185 217 249 281 313 345 377 409 441 473 505

0

1

0

1

1

26 58 90 122 154 186 218 250 282 314 346 378 410 442 474 506

1

1

0

1

1

27 59 91 123 155 187 219 251 283 315 347 379 411 443 475 507

0

0

1

1

1

28 60 92 124 156 188 220 252 284 316 348 380 412 444 476 508

1

0

1

1

1

29 61 93 125 157 189 221 253 285 317 349 381 413 445 477 509

0

1

1

1

1

30 62 94 126 158 190 222 254 286 318 350 382 414 446 478 510

1

1

1

1

1

31 63 95 127 159 191 223 255 287 319 351 383 415 447 479 511

Table 2: DIP switch address settings

10

2 3 4 5

1

8

6 7

9

ON

Address Setting Examples

Channel 2

10

2 3 4 5

1

8

6 7

9

ON

Channel 14

10

2 3 4 5

1

8

6 7

9

ON

Channel 46

10

2 3 4 5

1

8

6 7

9

ON

Channel 100

Summary of Contents for CYCLO 04 DMX

Page 1: ...m a r ti na r c h i t e c t u r a l Cyclo 04 DMX user manual...

Page 2: ...13 850 5 4 2003 Martin Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means with out permission in writing from Martin Professional A S Den...

Page 3: ...STAND ALONE OPERATION 11 Set the fixture to stand alone operation 11 DIP switch settings in stand alone mode 12 Program selection 12 Master slave 12 Program examples 14 DMX OPERATION 16 Connecting a D...

Page 4: ...en blue and white tubes Bright output Long lamp life of 20 000 hours Note It is important to read this manual through before you attempt to install this product SAFETY INFORMATION Warning This product...

Page 5: ...technician Protection from burns and fire Provide a minimum clearance of 0 1 meters 4 inches around the fixture Do not modify the fixture or install other than genuine Martin parts Do not operate the...

Page 6: ...nd connect it to AC and dimmer power These procedures shall be performed by qualified professionals To mount the fixture 1 Loosen the two Philips screws holding the mounting plate to the fixture 2 Rem...

Page 7: ...FI circuit breaker A normal 30 mA HPFI circuit breaker normally trips because of a current fault or leakage of approximately 20mA It is important that the installation is carried out correctly in orde...

Page 8: ...02 ENSTO male female cable 15 cm 5 9in P N 11501019 Be sure to refer and comply with local standards Some common AC cable configurations are Cyclo 04 DMX fixtures can be powered in series with other C...

Page 9: ...30 pieces P N 91611045 CAT5 network cables 10 m 32 8 ft x 15 pieces P N 91611045 Termination Plug RJ 45 P N 91613028 Note Mixing cables of different impedances and other characteristics not isolated b...

Page 10: ...andom flicker or other unexplained control problems insert a female termination plug P N 91613018 into the IN socket of the first fixture FLUORESCENT TUBES Burning in new tubes In order to obtain the...

Page 11: ...linked together and scene changes on all fixtures can be synchronously triggered by a master fixture SET THE F IXT URE TO STAND ALONE OPE RAT ION Stand alone operation is enabled by setting pin 10 on...

Page 12: ...irst reach 100 and they will meet at 50 M A S T E R S L A V E When a fixture is set to master DIP switch pin 9 is off it will transmit a synchronizing signal to slave fixtures over the data link whene...

Page 13: ...ly Scene numbering always starts at 0 and a maximum number of 8 scenes 0 7 can be set with all colors enabled and crossfade 0 Each scene can be seen as a translation from one output to another this tr...

Page 14: ...mple 1 DIP switch 7 is set to OFF crossfade 0 and only white is selected White Scene 010101010101 Example 2 DIP switch 7 is set to OFF crossfade 0 and white and red is selected White _ _ _ _ _ _ Red _...

Page 15: ...Example 5 The rainbow effect is achieved by selecting red green blue and DIP switch 7 is set to ON crossfade 50 red green blue Scene 012012012012012012012012012...

Page 16: ...Connect a data cable from the Cyclo 04 DMX to the control device s data output If the control device does not have an RJ 45 socket then you may need to purchase or wire an XLR to RJ45 converter For wi...

Page 17: ...set to 100 the Imager uses channels 100 101 102 103 and 104 Be sure to allow adequate channels when setting the control address If control channels for one fixture overlap control channels for another...

Page 18: ...141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1...

Page 19: ...Cyclo 04 DMX user manual 19 INTENSITY CONT ROL The intensity of the individual colors can be set from minimum to maximum on channels 1 to 4...

Page 20: ...00 White intensity Tube off Intensity 1 100 Intensity 100 2 0 2 3 252 253 255 0 1 99 100 Red intensity Tube off Intensity 1 100 Intensity 100 3 0 2 3 252 253 255 0 1 99 100 Green intensity Tube off In...

Page 21: ...s 3x28W Expected lamp life 20000 hours POWER AC power 198 V 254 V 50 60 Hz Maximum power and current 230 V 50 Hz 0 56 A 128 watts AC input EnstoNet Installation System connector plug not supplied THER...

Page 22: ...91613028 ENSTO 3 pole 16A 250V male connector P N 05347202 ENSTO 3 pole 16A 250V female connector P N 05327202 RJ 45 connector 15 cm 5 9 in P N 11840088 ENSTO Male female cable 15 cm 5 9in P N 115010...

Page 23: ......

Page 24: ...www martin architectural com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...