D I P - S W I T C H S E T T I N G S I N S T A N D - A L O N E
M O D E
P R O G R A M S E L E C T I O N
DIP-switch 1 to 4 each controls a single tube, and these DIP-switches can
be combined to activate more than one tube. If DIP-switch 7 is set to OFF
(crossfade@0%) then the tube will turn fully off before it fades in (or
alternatively when more tubes are selected, the next tube will fade in).
If DIP-switch 7 is set to ON (crossfade@50%) the tube will only fade down to
50% before it fades to full again (or alternatively when more tubes are
selected, the next tube will fade in when the first reach 100% and they "will
meet" at 50%)
M A S T E R / S L A V E
When a fixture is set to master (DIP-switch pin 9 is off), it will transmit a
synchronizing signal to slave fixtures over the data link whenever it changes
to the next scene. Slave fixtures (DIP-switch pin 9 is set on) only change
scenes when they receive synchronization signals from the master fixture.
Pin
Function
1
White
2
Red
3
Green
4
Blue
5 & 6
Program speed
Pin 6
Pin 5
Speed
Off
Off
Full speed (1 sec. pr. state)
Off
On
1/5 speed (5 sec. pr. state)
On
Off
1/10 speed (10 sec. pr. state)
On
On
1/30 speed (30 sec. pr. state)
7
OFF = crossfade@0%, ON = crossfade@50%
8
OFF = Run program, ON = Pause program
9
OFF = Master, ON = Slave
10
ON = Stand Alone mode.
Table 1. DIP-switch settings in stand-alone mode