background image

The slave program will be as set by its DIP-switch, so to have a master and
a slave run the same program, their DIP-switch settings have to be the same
(apart from the Master/Slave setting).

The synchronization signal is the same as used by other Mar tin
Architectural products, so this enables the stand-alone functionality to be
used with a range of other Martin products.

To have a single fixture run alone, it must be set to master. Slave fixtures
must not be connected to more than one master.

A d v a n c e d   m a s t e r / s l a v e

To make more advanced schemes, it is important to understand how scenes
are numbered. The scene pattern is always established in the sequence
white to red to green to blue. This means that if white is enabled, it will
always be placed first in the program. When crossfade@0% is selected,
e a c h   c o l o r   t a ke s   u p   t w o   s c e n e s   ( fa d e   i n   a n d   fa d e   o u t ) .   W h e n
crossfade@50% is selected, each color takes up one scene (fade in only).
Scene numbering always starts at 0, and a maximum number of 8 scenes (0
- 7) can be set, with all colors enabled and crossfade@0%.

Each scene can be seen as a translation from one output to another, this
translation is called a fade, and the time of the fade is set by the speed
setting of the DIP-switch. When a fixture is in slave mode, each new fade is
initiated by a synchronization signal received from the master. When the
slave receives a synchronization signal, and initiates a fade, it will not act on
new synchronization pulses, until the fade is complete.

If a slave fixture has:

1 Fewer scenes than the master fixture, it will run these in a cycle

continuously, until the master fixture signals that the program should start

from the beginning again.

2 More scenes than the master, then the additional scenes will never run,

because the program will reset to the first scene when the master starts its

program from the beginning.

Here is an example of what will happen when a slave fixture has fewer
scenes than the master fixture:

Scene pattern

Master with 7 scenes

01234560123456012...

Slave with 3 scenes

01201200120120012...

Summary of Contents for CYCLO 04 DMX

Page 1: ...m a r ti na r c h i t e c t u r a l Cyclo 04 DMX user manual...

Page 2: ...13 850 5 4 2003 Martin Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means with out permission in writing from Martin Professional A S Den...

Page 3: ...STAND ALONE OPERATION 11 Set the fixture to stand alone operation 11 DIP switch settings in stand alone mode 12 Program selection 12 Master slave 12 Program examples 14 DMX OPERATION 16 Connecting a D...

Page 4: ...en blue and white tubes Bright output Long lamp life of 20 000 hours Note It is important to read this manual through before you attempt to install this product SAFETY INFORMATION Warning This product...

Page 5: ...technician Protection from burns and fire Provide a minimum clearance of 0 1 meters 4 inches around the fixture Do not modify the fixture or install other than genuine Martin parts Do not operate the...

Page 6: ...nd connect it to AC and dimmer power These procedures shall be performed by qualified professionals To mount the fixture 1 Loosen the two Philips screws holding the mounting plate to the fixture 2 Rem...

Page 7: ...FI circuit breaker A normal 30 mA HPFI circuit breaker normally trips because of a current fault or leakage of approximately 20mA It is important that the installation is carried out correctly in orde...

Page 8: ...02 ENSTO male female cable 15 cm 5 9in P N 11501019 Be sure to refer and comply with local standards Some common AC cable configurations are Cyclo 04 DMX fixtures can be powered in series with other C...

Page 9: ...30 pieces P N 91611045 CAT5 network cables 10 m 32 8 ft x 15 pieces P N 91611045 Termination Plug RJ 45 P N 91613028 Note Mixing cables of different impedances and other characteristics not isolated b...

Page 10: ...andom flicker or other unexplained control problems insert a female termination plug P N 91613018 into the IN socket of the first fixture FLUORESCENT TUBES Burning in new tubes In order to obtain the...

Page 11: ...linked together and scene changes on all fixtures can be synchronously triggered by a master fixture SET THE F IXT URE TO STAND ALONE OPE RAT ION Stand alone operation is enabled by setting pin 10 on...

Page 12: ...irst reach 100 and they will meet at 50 M A S T E R S L A V E When a fixture is set to master DIP switch pin 9 is off it will transmit a synchronizing signal to slave fixtures over the data link whene...

Page 13: ...ly Scene numbering always starts at 0 and a maximum number of 8 scenes 0 7 can be set with all colors enabled and crossfade 0 Each scene can be seen as a translation from one output to another this tr...

Page 14: ...mple 1 DIP switch 7 is set to OFF crossfade 0 and only white is selected White Scene 010101010101 Example 2 DIP switch 7 is set to OFF crossfade 0 and white and red is selected White _ _ _ _ _ _ Red _...

Page 15: ...Example 5 The rainbow effect is achieved by selecting red green blue and DIP switch 7 is set to ON crossfade 50 red green blue Scene 012012012012012012012012012...

Page 16: ...Connect a data cable from the Cyclo 04 DMX to the control device s data output If the control device does not have an RJ 45 socket then you may need to purchase or wire an XLR to RJ45 converter For wi...

Page 17: ...set to 100 the Imager uses channels 100 101 102 103 and 104 Be sure to allow adequate channels when setting the control address If control channels for one fixture overlap control channels for another...

Page 18: ...141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1...

Page 19: ...Cyclo 04 DMX user manual 19 INTENSITY CONT ROL The intensity of the individual colors can be set from minimum to maximum on channels 1 to 4...

Page 20: ...00 White intensity Tube off Intensity 1 100 Intensity 100 2 0 2 3 252 253 255 0 1 99 100 Red intensity Tube off Intensity 1 100 Intensity 100 3 0 2 3 252 253 255 0 1 99 100 Green intensity Tube off In...

Page 21: ...s 3x28W Expected lamp life 20000 hours POWER AC power 198 V 254 V 50 60 Hz Maximum power and current 230 V 50 Hz 0 56 A 128 watts AC input EnstoNet Installation System connector plug not supplied THER...

Page 22: ...91613028 ENSTO 3 pole 16A 250V male connector P N 05347202 ENSTO 3 pole 16A 250V female connector P N 05327202 RJ 45 connector 15 cm 5 9 in P N 11840088 ENSTO Male female cable 15 cm 5 9in P N 115010...

Page 23: ......

Page 24: ...www martin architectural com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...

Reviews: