7. TROUBLESHOOTING:
Please make sure that your phone
’
s Bluetooth is working. All the buttons in the app get faded or
their colors are changed when you touch them. Verify that your phone
’
s touchscreen works
properly, and If you use a case or screen protector for your phone, take them off temporarily be-
fore troubleshooting.
19
Problem
Solution
The app doesn
’
t find the Smart Clean after search-
ing.
1
–
check to see if the operating status light on the ORIOLE controller box
(JCA00
-
009001) is on. If the light is off :
•
Disconnect the connector between the power harness and the planters
harness and check the voltage at the power harness
’
s end to be 12V.
The power harness has an in
-
line fuse . Check the fuse and your tractor
power supply if you don
’
t see any voltage .
•
If there is voltage at the end of the power harness, then check the polar-
ity of the voltage. Make sure that the red wire is connected to positive
and the black wire is connected to negative.
2
–
If the operating status light is on, then reset the circuit by turning off the
power supply or disconnecting the connector between the power and plant-
ers harnesses.
3
–
Close the app, and reopen it.
4
–
Update your device
’
s Operating System (OS) version to ensure it uses
latest Bluetooth drivers.
The app finds the Smart Clean, but it doesn
’
t con-
nect.
This happens when another phone has been paired with the system. Reset
the circuit by turning off the power supply or disconnecting the connector
between power and planters harnesses to unpair the other phone.
The compressor works continuously and doesn
’
t
build up pressure.
Check all the tubing and connections for air leaks .
The compressor works continuously and does build
up pressure.
Verify the compressor automatic switch is wired correctly and works proper-
ly according to the compressor manufacturer
’
s instruction included with the
compressor.
Air is leaking from the directional valve mufflers.
This happens when one or more air cylinders are defective and have internal
leaks. To find the defective cylinders, adjust to 100% pressure and select the
Down position on the main page of the app. Then test each individual cylin-
der by unplugging the cylinder
’
s bottom air inlet. If air leaks out from the
cylinder bottom air inlet, the cylinder has an internal leak and needs to be
replaced.
The
“
Down
”
setting lift the row units and the
“
Up
”
setting lower them.
It happens In some of the bracket designs, where the stationery end of the
cylinder is located under the row cleaner pivot point. Switching the air outlet
tubes on the plumbing box will fix the problem.
App doesn
’
t respond and appears frozen.
Check OS version . Smart Clean requires iOS 11 or later or the latest version
of Android . Some older device's may not be compatible. Remove phone
case to verify it is not prohibiting your touch screen.