AC power
9
Fuses
The MAC 2000 Wash is supplied with:
• two 20 AT (time delay) main fuses for use with AC supplies of 100 - 130 volts.
• two 15 A main fuses for use with AC supplies of 200 - 250 volts.
Install the appropriate fuses in the holders near the power switch.
Power connection
Important! Connect the MAC 2000 Wash directly to AC power. Do not connect it to a dimmer system;
doing so may damage the fixture.
You may need to install a cord cap that fits your supply on the power cable. A 3-prong grounding-type plug
must be installed following the manufacturer’s instructions. The table shows some possible pin identification
schemes; if the pins are not clearly identified, or if you have any doubts about proper installation, consult a
qualified electrician.
To apply power, set the power switch on the base to the “I” position.
Reduced power function
The MAC 2000 Wash has an automatic power reduction function, which reduces the consumption to 700W
if the shutter/dimmer is closed for more than 10 seconds. This not only increases the lamp life, but also
further decreases the overall noise emission of the fixture.
Wire Color
Pin
Symbol
Screw (US)
brown
live
L
yellow or brass
blue
neutral
N
silver
yellow/green
ground green
Table 1: Cord cap connections