Display messages
41
D
ISPLAY
MESSAGES
Message
Appears when...
What to do
R S T
(
Reset)
... the fixture is indexing effects at
startup.
Wait for reset to complete.
S R S T
(Serial reset)
... the fixture has received a reset
command from the controller.
Wait for reset to complete. Set
PERS/dRES to OFF to prevent
accidental reset commands.
H O M E
... the effects have been indexed and are
moving to their default positions.
Wait a few moments.
O P E N
...the lamp access cover is not fully
closed.
Verify that the lamp access cover is
locked in place.
L E R R
(Lamp error)
... the lamp does not ignite within 10
minutes of receiving the ‘Lamp ON’
command. Likely reasons are a missing
or defective lamp, or insufficient AC
voltage.
Check the lamp. Check that the
voltage and frequency settings match
the local supply.
M E R R
(Memory error)
...the EEPROM memory cannot be read.
Contact Martin service personnel for
assistance.
S h E R
(Short error)
... the fixture detects the lamp is ON but
no ‘Lamp ON’ command has been
received. This can occur if the lamp relay
is stuck or if the lamp-power feedback
circuit fails. The fixture may be operated
but remote lamp on/off may be affected.
Contact Martin service personnel for
assistance.
b T E R
(Base temperature error)
H T E R
(Head temperature error)
... there is a fault with the temperature
sensor in the base or head.
Contact Martin service personnel for
assistance.
F b E P
(Feedback error pan)
F b E T
(Feedback error tilt)
F b E R
(Feedback error pan/tilt)
...pan (FbEp), tilt (FbET) or both (FbER)
feedback circuits are malfunctioning. It is
still possible to operate the fixture,
although it switches to “safe” mode with
reduced maximum speed, thus
preventing the fixture from losing track of
its home position (losing step).
Contact Martin service personnel for
assistance.
P A E R
(Pan time-out)
T I E R
(Tilt time-out)
C Y E R
(Cyan time-out)
M A E R
(Magenta time-out)
Y E E R
(Yellow time-out)
C T E R
(CTC time-out)
C 1 E R
(Color wheel 1)
C 2 E R
(Color wheel 2/Dimmer
wheel time-out)
Z O E R
(Zoom time-out)
...the electric indexing circuit is
malfunctioning. The fixture will, after the
time-out, establish a mechanical stop,
and continue to work normally.
Reset fixture. Contact Martin service
personnel if problem continues.
R B E R
...the barndoor rotation mechanism is
malfunctioning.
Reset fixture. Contact Martin service
personnel if problem continues.
S 3 S C
S 4 S C
S 5 S C
S 6 S C
S 7 S C
S 8 S C
S 9 S C
S 1 0 S
S 1 1 S
S 1 2 S
...an effect does not move away from the
index position under reset, a sensor or
micro-switch circuit is shorted, or a
micro-switch is stuck or connected
incorrectly.
Contact Martin service personnel for
assistance.
R A M E
...there is an onboard RAM memory
error.
Contact Martin service personnel for
assistance.
O P E R
...there is an onboard programming
error.
Contact Martin service personnel for
assistance.
Table 2: Display messages
Summary of Contents for MAC 2000 Wash
Page 1: ...MAC 2000 Wash user manual...