background image

Service and maintenance

35

Warning! The Extube is IP65 rated. This means that it will withstand 
water projections, but do not expose it to high-pressure water jets or 
immerse it in water or any other liquid.

Clean the Extube’s housing and front glass with a soft cloth dampened 
with a solution of water and a mild detergent such as car shampoo. Take 
care not to damage seals and wiring during cleaning. Do not use products 
that contain solvents, abrasives or caustic agents for cleaning, as they can 
cause surface damage to the fixture and its front cover.

Diffusers

Important!

To avoid damaging the aluminum alloy housing, use plastic bicycle 
tire levers – not bare metal tools – to lever off front glass retaining 
strips.

Extube fixtures are provided with no diffuser to give a Very Narrow beam 
angle or with a Narrow, Medium or Wide diffuser filter installed at the 
factory. Diffuser filters can be identified by notches at one end as follows:

• 1 notch – Narrow

• 2 notches – Medium

• 3 notches – Wide

If you need to replace or install a diffuser filter:

1. Cut power to the installation and allow to cool for at least 20 minutes.

2. See Figure 13 on page 36. Look carefully under the metal strips on 

either side of the front glass. On one side of the front glass, the strip is 
an integral part of the housing and there is no gap between strip and 
housing. On the other side of the front glass, there is an extra ridge 
under the outer edge of the strip and a narrow gap where the strip 
meets the housing. This strip is the front cover retaining strip and can 
be levered off the housing to release the front glass.

3. Using plastic bicycle tire levers or similar tools that will not damage the 

Extube’s metal alloy surfaces between the front cover retaining strip 
and the housing, lever up and remove the front cover retaining strip. If 
plastic levers are not available, large flat-bladed screwdrivers with a 
piece of paper folded at least 4 times and then folded over the blade to 
prevent metal-to-metal contact can be used in an emergency, but 

Summary of Contents for Extube

Page 1: ...Extube user manual TM...

Page 2: ...ss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The Martin logo the Martin name and all other trad...

Page 3: ...e only It is not for household use This product presents risks of severe injury or death due to fire hazards electric shock and falls Read this manual before installing powering or servicing the fixtu...

Page 4: ...side the input cap are live when power is applied to the power cable Do not apply power to the cable unless the input cap is installed on a fixture as described in this manual Terminals inside the con...

Page 5: ...sure unrestricted airflow around the fixture P R O T E C T I O N F R O M I N J U R Y Do not look at exposed LEDs from a distance of less than 2 2 m 7 ft 3 in from the front surface of the fixture with...

Page 6: ...and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment as amended by Directive 2003 108 EC where applicable Help preserve the environment Ensure that this product i...

Page 7: ...C power 20 Connecting to power 21 Control data link 23 Connecting the data link 25 Fixture setup 26 Communication between MUM and fixtures 26 Fixture information 28 Fixture settings 29 Operation 33 Am...

Page 8: ...8 Extube user manual Notes...

Page 9: ...s 25 W LED power and 348 lumens total output at very narrow beam angle from 300 mm models Four models available one Very Narrow beam angle model with no diffuser fitted and Narrow Medium and Wide beam...

Page 10: ...it Input cap with 1 8 m 5 ft 10 in power and data cable tails End cap with integral DMX data link termination Four locking clips for securing input and end caps This user manual Using for the first ti...

Page 11: ...lus an adequate safety margin To ensure a waterproof seal the supplied locking clips must be used to fasten fixtures to each other and to fasten input and end caps onto fixtures Install fixtures on DI...

Page 12: ...n reach temperatures up to 90 C 194 F Restrict public access or locate the fixture so that it cannot accidentally be touched Mounting the fixture DIN rail The Extube is designed to be mounted on stand...

Page 13: ...a surface using DIN rail 1 Fasten the DIN rail securely to the mounting surface 2 See Figure 2 The Extube mounting bracket has a hooked profile on one side Hook this profile over the top of the DIN ra...

Page 14: ...mounting holes see C in Figure 4 so that Extube mounting clamps rest against these screws and secure the fixture Safety attachment When installing Extubes in an area where they could fall and cause d...

Page 15: ...ckets of all interconnected fixtures Engage the Allen key in the screw inside each hole apply a little inwards pressure and twist a quarter turn clockwise to release the tilt lock 2 Adjust the fixture...

Page 16: ...at the tilt lock is applied on all the mounting brackets See Figure 7 A small button on the opposite side of the mounting bracket to the tilt lock screw indicates whether the tilt lock is applied or n...

Page 17: ...ine of Extube fixtures Warning Do not exceed the maximum length specified under Maximum interconnected length per power input on page 43 for a line of Extube fixtures connected to each other and suppl...

Page 18: ...d and secured with two clips per cap Extension kits See Figure 10 It is possible to create a gap in a line of Extube fixtures to pass a door window or corner for example but keep the fixtures connecte...

Page 19: ...etails Output and input caps must be secured with two locking clips each Cable entry and drip loops Ensure that cables enter fixtures from below See Figure 11 If necessary form a drip loop in the cabl...

Page 20: ...grounded earthed The AC mains power distribution system must be fitted with both current overload and ground fault earth fault circuit breakers as well as a means to isolate fixtures from power and lo...

Page 21: ...input cap are live when power is applied to the power cable Terminals inside the connector at the output end of the fixture are live when power is applied to the fixture Do not apply power to the powe...

Page 22: ...cks before applying power to the installation Power plug If you decide to fit the supplied power cable with a plug that is suitable for your AC mains power outlets install a grounding type earthed plu...

Page 23: ...imum permitted control data cable length before a control signal amplifier is required is 500 meters 1640 ft An optically isolated amplifier splitter such as the Martin RS 485 Opto Splitter P N 907580...

Page 24: ...dy of XLR connectors RJ 45 connection RJ 45 connectors are suitable if the DMX controller has RJ 45 output sockets CAT 5e network cable is recommended in this case RJ 45 cable connector pins are numbe...

Page 25: ...ata link respecting the above color code If required install an XLR or RJ 45 DMX input connector on the data cable for connection to a DMX control device respecting the pinouts described in Data conne...

Page 26: ...the MUM application a DABS1 adaptor and interface cables These are available as a set from Martin P N 90758090 2 Connect the DABS1 adaptor to your PC using the USB cable supplied in the set 3 Connect...

Page 27: ...p the installation segments can be controlled separately or put into groups MUM lets you select which segment to communicate with and gives you information about segments In the example below a MUM is...

Page 28: ...hows the total number of hours since manufacture and one resettable counter shows the number of hours since the counter was last reset The Extube s software monitors operation If it detects an error i...

Page 29: ...rows and changing the DMX mode setting for each pixel Individual and grouped control of segments The Fixture settings window lets you control 300 mm Extubes or 300 mm segments of 1200 mm Extubes indiv...

Page 30: ...Segment auto configure set to Disabled when you are not setting DMX addresses Grouped control of one complete line of Extubes If you intend to use a DMX controller to operate one Extube or one line o...

Page 31: ...ta link Depending on the DMX mode you have selected the installation will use 3 or 4 DMX channels per pixel starting at channel 1 on your controller Multiple lines of Extubes If you intend to use one...

Page 32: ...LED and PCB temperatures for each segment can be displayed in MUM s Monitor window LED Test The Extube s LEDs can be activated without a DMX controller for test purposes in MUM s LED Test window Auto...

Page 33: ...e a little heat and help protect circuits and components from the effects of low temperature Status indication at power up When power is applied to an Extube installation with no DMX signal present LE...

Page 34: ...o wear and tear over the life of the fixture resulting in gradual changes in color rendition for example The extent of wear and tear depends heavily on operating conditions and environment so it is im...

Page 35: ...ches at one end as follows 1 notch Narrow 2 notches Medium 3 notches Wide If you need to replace or install a diffuser filter 1 Cut power to the installation and allow to cool for at least 20 minutes...

Page 36: ...eat care must be taken Damage caused by metal levers is not covered by the product warranty 4 See Figure 14 Hinge the front glass up and out of the housing Figure 13 Opening the front glass Figure 14...

Page 37: ...front glass securely Software installation It may be necessary to upload new software i e firmware to the Extube if you believe that the product has a software related fault or if you want to update t...

Page 38: ...and connected via the DMX link 2 Upload the fixture software as described in the uploader s help file or user documentation 3 Disconnect the uploader hardware and reconnect the fixture to the DMX lin...

Page 39: ...n 1 0 255 0 100 Red Intensity 0 100 2 0 255 0 100 Green Intensity 0 100 3 0 255 0 100 Blue Intensity 0 100 Start code 0 Channel Value Percent Function 1 0 255 0 100 Red Intensity 0 100 2 0 255 0 100 G...

Page 40: ...ion 1 0 255 0 100 Hue Red Orange Amber Yellow Green Cyan Blue Indigo Violet Magenta Red 2 0 255 0 100 Saturation Zero white Full 3 0 255 0 100 Intensity Intensity 0 100 Start code 0 Channel Value Perc...

Page 41: ...ddressing Check fixture is set to correct DMX mode Check number of channels required by fixture s DMX mode and check fixture addresses Fixture defective Have faulty fixture serviced by Martin service...

Page 42: ...ontrol modes RGB RGBW HSI HSIC Control system DMX DMX channels 3 4 Grouped pixel control options 1 x 3 all as one group on 300 mm models 1 x 12 all as one group or 4 x 3 on 1200 mm models DMX address...

Page 43: ...brackets PA6 nylon End covers and caps PA6 nylon Protection rating IP 65 In s ta ll at io n Orientation Any Vertical aiming 90 Mounting 35 mm top hat profile DIN rail Maximum interconnected length pe...

Page 44: ...bient temperature 25 C 77 F Measurements made at nominal voltage Allow for a deviation of 10 T he r m a l Cooling Convection Maximum ambient temperature Ta max 45 C 113 F Minimum ambient temperature T...

Page 45: ...ower Connection Kit US type P N 91610087 Extube 300 mm Aluminum Narrow P N 90352200 Extube 300 mm Aluminum Medium P N 90352300 Extube 300 mm Aluminum Wide P N 90352400 Extube 300 mm Aluminum no diffus...

Page 46: ...m White no diffuser P N 90352512 Custom colors are available by special order please contact your Martin distributor for details Specifications subject to change without notice Please see www martin c...

Page 47: ......

Page 48: ......

Reviews: