Other functions

 

 

HOLD

 

-

  this  is  available  if  readings  need  to  be  frozen  during  measurement. 

Activate as follows:

 

 
 

 

Press      during measurement. HOLD will be 

displayed. Withdraw the probe from the bale 

and the reading will remain on the display.

 

 
 
 
 
 

 

 

 

Reference Measurement 

-

 

this is ideal for when testing a large number of bales. 

The meter can be set to show the difference in moisture level from a reference 

reading.  This  makes  it  much  quicker  to  give  an  indication  of  the  moisture 

variability when doing a lot of tests. 

 

 
 
 

Take the first reading which is to be used as 

the  reference.  While  the  reading  is 

displayed, press and hold        for 2 seconds 

to  enter  Reference  Mode.  Take  the  second 

reading.  The  display  will  be  as  shown.  The 

top  number  is  the  second  moisture  reading 

and  the  lower  value  is  the  difference 

between  the  reading  and  the  reference 

reading.  To  return  to  normal  measurement 

mode, press       again. 

 

 
 

Interpreting Readings

 

Balemaster readings can help a professional make an informed judgement as to 

the  moisture  condition  of  the  bale.  Readings  are  not  definitive  and  can  be 

affected by external factors such as bale density and consistency. 

 

 

 

 

Taking a Moisture Reading

 

 

Summary of Contents for Protimeter Balemaster

Page 1: ...Martin Lishman Balemaster Distributed by Martin Lishman Ltd Tel 44 0 1778 426600 www martinlishman com Instruction Manual GRN6165 Professional Crop Moisture Measurement...

Page 2: ...the battery if the instrument is not used for long periods Calibration Check The meter calibration can be checked by the user with the Protimeter Calcheck Device Part No BLD5086 and a 2 pin moisture p...

Page 3: ...e Balemaster readings can help a professional make an informed judgement as to the moisture condition of the bale Readings are not definitive and can be affected by external factors such as bale densi...

Page 4: ...ng as well as colour LED and moisture range description will show as follows Switch the meter off by pressing and holding or leave and it will switch off automatically after the set time see Page 6 Ta...

Page 5: ...ity when doing a lot of tests Take the first reading which is to be used as the reference While the reading is displayed press and hold for 2 seconds to enter Reference Mode Take the second reading Th...

Page 6: ...ay shows and then release both buttons The screen will then scroll through the existing settings showing each one for 2 seconds If there is no key press within the 2 seconds it moves to the next setti...

Page 7: ...Probe 1 5m not pictured Part No GRN6153 Stainless steel fast response probe used with the Balemaster to check the temperature of stored grain Taking a temperature probe reading Push the probe into th...

Page 8: ...e imburse any costs associated with a warranty claim if these costs have been incurred without agreement in advance Under the terms of warranty for the unit under no circumstances will liability excee...

Reviews: