Meter Settings

 

Default Settings

 

The  Balemaster

 

is  supplied  ready

-

to

-

use  with  moisture  descriptions,  buzzer 

tone and backlight on, auto

-

off time set at 2 minutes and temperature in °C. 

 

 

To alter default settings

 

enter Settings Mode: 

 

With the meter switched off, press and hold 

 

 and then press 

 

 

. Hold both 

buttons until the Settings Mode display shows and then release both buttons. 

 

 
 
 
 

 
 
 
 

 

The  screen  will  then  scroll  through  the  existing  settings,  showing  each  one  for  2 

seconds. If there is no key press within the 2 seconds it moves to the next setting:

 

 
 
 
 
 
 
 
 
 
 
 

 

 

 

Moisture range 

descriptions ON

 

Buzzer Tone ON

 

Backlight ON

 

Auto Off time delay 2 mins

 

To set turn off time between 1

-

mins press      and then press     .

 

If set at 0, turn off is manual by 

pressing and holding      for 5 secs.

 

Temperature readings in °C

 

To change to °F, press     and 

then press

 

To change the settings above to OFF, press      and then press 

 

Summary of Contents for Protimeter Balemaster

Page 1: ...Martin Lishman Balemaster Distributed by Martin Lishman Ltd Tel 44 0 1778 426600 www martinlishman com Instruction Manual GRN6165 Professional Crop Moisture Measurement...

Page 2: ...the battery if the instrument is not used for long periods Calibration Check The meter calibration can be checked by the user with the Protimeter Calcheck Device Part No BLD5086 and a 2 pin moisture p...

Page 3: ...e Balemaster readings can help a professional make an informed judgement as to the moisture condition of the bale Readings are not definitive and can be affected by external factors such as bale densi...

Page 4: ...ng as well as colour LED and moisture range description will show as follows Switch the meter off by pressing and holding or leave and it will switch off automatically after the set time see Page 6 Ta...

Page 5: ...ity when doing a lot of tests Take the first reading which is to be used as the reference While the reading is displayed press and hold for 2 seconds to enter Reference Mode Take the second reading Th...

Page 6: ...ay shows and then release both buttons The screen will then scroll through the existing settings showing each one for 2 seconds If there is no key press within the 2 seconds it moves to the next setti...

Page 7: ...Probe 1 5m not pictured Part No GRN6153 Stainless steel fast response probe used with the Balemaster to check the temperature of stored grain Taking a temperature probe reading Push the probe into th...

Page 8: ...e imburse any costs associated with a warranty claim if these costs have been incurred without agreement in advance Under the terms of warranty for the unit under no circumstances will liability excee...

Reviews: