CH7C and CH7D have a single speed motor. CH7C models have a toast time of a 8 seconds
heel and 11 seconds crown. CH7D models have a speed of 23 seconds both crown and heel.
CH7F has a 9 second toast time both crown and heel. The CH7F-15 has a 15 second toast time.
CH7G models have a 3.5 minute toast time both crown and heel.
12. Test at least 3 buns before putting the toaster into service. Uniform surface toasting and bun
temperature are achieved when the gap described in step 10 is set correctly.
OPERATION (UNITS WITH LED CONTROL)
1. The toaster is operated by pressing and releasing the “I/O” Button of the control. “Lo” will be
displayed.
2. The display of the control will show “Rdy” once the toaster is up to temperature. (Approximately
15 minutes.)
3. For proper operation, insert heels on the side of the toaster marked "HEEL", and crowns on the
opposite side.
4. To turn off, press and hold the “I/O” Button. “Hi” will be displayed which means unit is still too hot
to remove any parts. Once the toaster has cooled (approximately 30 minutes), the display will
show “Off.”
5. The LED Control will indicate important information:
A. Press and release either the Crown or the Booster Button, the pre-programmed
temperature settings will flash. This will display for 5 seconds or until another button is
pressed.
B. Press and hold either the Crown or the Booster Button for 3 seconds, the actual platen
temperatures will be displayed. This will display until another button is pressed.
6. Definitions of various displays:
“Off”
Unit is off and not operating.
“Lo”
Heater platens have not reached programmed set temperature.
“Rdy”
Unit has reached programmed set temperature and is ready to toast.
“Hi”
Unit is off and too hot to touch most removeable parts.
“AL1”
This is an alarm message that indicates the Center Platen Probe is disconnected
or defective.
“AL2”
This is an alarm message that indicates the Booster Platen Probe is disconnected
or defective.
“AL3”
This is an alarm message that indicates the Center Platen is too hot. Normally
this means the relay has failed. Unit shuts off.
“AL4”
This is an alarm message that indicates the Booster Platen is too hot. Normally
this means the relay has failed. Unit shuts off.