START-UP 

 

This product has been assembled and tested at the 

factory prior to shipping. The following procedures should 

be performed to assure its performance. Before 

continuing with the start-up, it is important to recognize the 

safety controls furnished with the unit. 

 

 

 

 

 

 

 

 WARNING 

Prevent hazard of electrical shock. More than one 

disconnect switch may be required to de-energize this 

product. 

 

 WARNING 

 

The following items must all be completed by a qualified 

installer and checked off when completed 

 

A.  Re-check that the product has been installed properly 

and is level and secure. 

B.  Check all terminal screws are tight and field wiring is 

connected in accordance to National Electrical Code 

and wired per the enclosed wiring diagram. For 

electric heated models, ensure that the coils are 

secured  and not touching each other on any metal 

surface. 

C.  Verify proper voltage prior to powering the product. 

(See product label for reference). 

D.  Check all field wired components “if supplied” are 

wired correctly. 

E.  Check that the inlet air supply and the discharge air 

supply are free of obstructions. 

F.  Check that all air filter(s) and/or air intake grille(s) are 

in place and installed properly, as originally shipped. 

G.  Verify voltage to the product once more and turn 

power on. 

H.  Regardless of whether the product is mounted on the 

inside or outside of the door opening, set the air 

directional vanes in the discharge nozzle slightly 

outward to approximately 10-15° towards the outside, 

or the wind load. (FIG. 4). 

 

 

 

 

 

I.  For products with control panels, turn the HOA (Hand-

On-Auto) selector switch to “On” position and open the 

door to energize the product. For products without a 

control panel or an On/Off switch, open the door to 

energize the product. 

J.  If heated products are installed, reference 

Heated 

Products Supplement

.  

K.  For three phase units, verify direction of rotation of 

blower wheels (note direction arrows on the blower 

wheel housing). Correct if needed by changing polarity 

of three phase power. 

FIG. 4 