background image

 

TROUBLESHOOTING MOTOR 

 

To determine if the motor is  in  good  operating condition,  compare measured motor  resistance at the motor 

terminals to the values shown below. 

 

 

HIGH SPEED (1750) MEDIUM SPEED (1650) LOW SPEED (1450)

Applicable 

Air Curtain 

Series

Mars Part # Manufacturer Part #

Brand

Motor Rating

HP

Voltage

Phase

Black Motor Wire  & White 

Motor Wire

-

-

03-001

7190-1682

Fasco

Nema 1

1/6

115

1

11.5

-

-

03-002

7190-1903

Fasco

Nema 1

1/6

115

1

8.4

-

-

03-003

7190-1825

Fasco

Nema 1

1/6

230

1

64

-

-

03-004

7190-1904

Fasco

Nema 1

1/6

230

1

44.6

-

-

Applicable 

Air Curtain 

Series

Mars Part # Manufacturer Part #

Brand

Motor Rating

HP

Voltage

Phase

White Motor Wire (T1) 

Black Motor Wire (T3)

White Motor Wire (T1) 

Black Motor Wire (T5)

White Motor Wire (T1) 

Black Motor Wire (T2)

03-010

34G928X169

Baldor

Washdown (IP54)

1/2

115

1

1.2

-

-

03-010

34G928X169

Baldor

Washdown (IP54)

1/2

208/230

1

4.6

-

-

03-005

7124-1175

Genteq

Nema 1

1/2

115

1

2.6

3.8

5.2

03-006

7124-1560

Genteq

Nema 1

1/2

208/230

1

9.9

15.9

22.5

03-007

48S17T439

Marathon

Nema 1

1/2

277

1

7.7

-

-

03-005

K055PWM1736C13H

Nidec

Nema 1

1/2

115

1

2.1

3.7

5.2

03-005

K055PWM1736C13H

US

Nema 1

1/2

115

1

5.3

3.7

5.4

03-006

US

Nema 1

1/2

208/230

1

8.7

18.2

24.2

Applicable 

Air Curtain 

Series

Mars Part # Manufacturer Part #

Brand

Motor Rating

HP

Voltage

Phase

White Motor Wire (T1) 

Black Motor Wire (T2)

White Motor Wire (T1) 

Black Motor Wire (T3)

-

03-021

35T276R025G1

Baldor

Washdown (IP54)

1

115

1

0.7

-

-

03-015-Baldor

35M316S174

Baldor

Nema 1

1

115

1

0.6

-

-

03-015-Baldor

35M316S174

Baldor

Nema 1

1

208/230

1

2.2

-

-

03-021

35T276R025G1

Baldor

Washdown (IP54)

1

208/230

1

2.8

-

-

03-014

7124-0985

Genteq

Nema 1

1

115

1

1.6

2.4

-

03-015

7124-1096

Genteq

Nema 1

1

208/230

1

6.5

9.2

-

03-015

-

Nidec

Nema 1

1

208/230

1

4.3

6.5

-

03-014

K55BWJZB-2362

US

Nema 1

1

115

1

1

2.1

-

03-015

-

US

Nema 1

1

208/230

1

3.2

6.3

-

Black Motor Wire (L1) 

Red Motor Wire (L2)

Black Motor Wire (L1) 

White Motor Wire (L3)

Red Motor Wire (L2) 

White Motor Wire (L3)

03-008

P55YYDHB-1527

US

Nema 1

1/2

208-230

3

16.1

16.1

16.1

03-008

P55YYDHB-1527

US

Nema 1

1/2

460

3

63.6

63.6

63.6

03-009

48T17T135

Marathon

Nema 1

1/2

575

3

136

136

136

03-017

56T17T5541

Marathon

Nema 1

1

208-230

3

4.3

4.3

4.3

03-017

56T17T5541

Marathon

Nema 1

1

460

3

16.5

16.5

16.5

03-018

56T17T5544

Marathon

Nema 1

1

575

3

26.6

26.6

26.6

03-022

35N127S902

Baldor

Washdown (IP54)

1

208-230

3

5.1

5.1

5.1

03-022

35N127S902

Baldor

Washdown (IP54)

1

460

3

19.8

19.8

19.8

03-026

165716

Century

Nema 1

3

208-230

3

1.5

1.5

1.5

03-026

165716

Century

Nema 1

3

460

3

5.7

5.7

5.7

03-028

35E92Y26

Baldor

Nema 1

3

575

3

9.2

9.2

9.2

03-110

36H110-2211G1

Baldor

Nema 1

1,2,3

208-230

3

3.5

3.5

3.5

03-110

36H110-2211G1

Baldor

Nema 1

1,2,3

460

3

13.5

13.5

13.5

03-055

37F932W828G1

Baldor

Nema 1

5

230

3

0.7

0.7

0.7

03-055

37F932W828G1

Baldor

Nema 1

5

460

3

2.4

2.4

2.4

03-046

37F909X889G1

Baldor

Nema 1

7

230

3

0.6

0.6

0.6

03-046

37F909X889G1

Baldor

Nema 1

7

460

3

1.6

1.6

1.6

03-033

U639A - 215TTFC6027 Marathon

Nema 1

10

208-230

3

0.4

0.4

0.4

03-033

U639A - 215TTFC6027 Marathon

Nema 1

10

460

3

1.2

1.2

1.2

03-074

GT1128A 170118.60

Marathon

Nema 1

25

575

3

0.5

0.5

0.5

BD

HV2, NH2, 

PH12

EP2

WMI

WMH

STD2, N2, 

PH10, QP10

Applicable 

Air Curtain 

Series

Mars Part #

HP

Voltage

Brand

Motor Rating

Manufacturer Part #

Phase

LEAD WIRE OHM READINGS

MOTOR WIRES OR TERMINAL (T) OHM READINGS

Single Phase Motors

MARS MOTOR RESISTANCE READINGS

Three Phase Motors

LPV2, LPN2

STD2, N2, 

PH10, QP10

HV2, NH2, 

PH12

Summary of Contents for LPN2 Series

Page 1: ...stamped air intake screen s The LPV2 models can be configured with an aluminum mesh filter s as an option The LPN2 models 25 and all LPN F models come standard with an aluminum mesh air intake filter...

Page 2: ...l other accessories from interior of unit prior to operating Severe unit damage will occur if these items are not removed prior to operation 2 Lay unit on its top with directional vanes pointing up an...

Page 3: ...uing with the start up it is important to recognize the safety controls furnished with the unit WARNING The following items must all be completed by a qualified installer and checked off when complete...

Page 4: ...nimize condensation and freezing for freezer applications We recommend the air curtain unit to not replace doors but work in conjunction with door opening sequence cycle Contact factory for details CA...

Page 5: ...on on intake or discharge Remove obstruction or move air curtain Power leads out of polarity Switch power leads to correct polarity 3 phase models only Blower motor rotating below normal speed Apply p...

Page 6: ...ma 1 1 115 1 1 6 2 4 03 015 7124 1096 Genteq Nema 1 1 208 230 1 6 5 9 2 03 015 Nidec Nema 1 1 208 230 1 4 3 6 5 03 014 K55BWJZB 2362 US Nema 1 1 115 1 1 2 1 03 015 US Nema 1 1 208 230 1 3 2 6 3 Black...

Page 7: ...omer may be responsible for transportation charges associated with replacement of failed part Mars does not warrant uninterrupted or error free operation of Mars product Under no circumstance is Mars...

Reviews: