background image

 

MAINTENANCE

 

 

Routine maintenance is required to keep this product 

operating at its peak performance and efficiency. Over 

time, the housing, air intake grille, air intake filter, blower 

wheels and motor(s) will accumulate a build up of dust, 

debris and other residue. It is imperative to keep these 

components clean. Failure to do so will not only lower 

operational efficiency and performance, but also reduce 

the useful life of the product. The time between cleanings 

depends on the application, location, and daily hours of 

use. On average, under normal use conditions, the 

product should require a thorough cleaning once every 

six (6) months.  

 

To clean the product, perform the following: 

 

1.  Verify the product has been disconnected from the 

power source. 

2.  Use a damp cloth and either a warm mild soapy water 

solution or bio-degradable degreaser, to wipe down the 

exterior components of the housing. 

3.  To access the interior of the product, remove the air 

intake grille(s)  and/or air intake filter(s).  This is 

accomplished by removing the screws on the face of the 

air intake grille(s)/filter(s). 

4.  Thoroughly clean the air intake grille(s)/filter(s). 

5.  Thoroughly wipe down the motor, blower wheels and 

blower wheel housings.  Be careful not to spray the 

motor with a water hose.  

6.  The motor(s) require no additional lubrication. They are 

permanently lubricated and feature double sealed ball 

bearings. 

7.  To re-install the product, reverse the procedures above. 

8.  Reconnect the power source to the product. 

9.  If you have any questions regarding the maintenance of 

the product, contact the manufacturer. 

 

SPECIAL APPLICATIONS 

 

Outdoor Installation 

 

For outdoor unit special consideration may be required 

for enclosure and other components to minimize damage 

caused by exposure to the outdoor elements. Contact 

factory for special construction and costing. 

 

Freezer and Cooler Installation 

 

Air curtain must be mounted on the warm side for optimal 

performance. LPV2 series with variable speed switch is 

strongly recommended to control the air curtain air flow 

velocity at the floor level. 

 

High humid areas may require de-humidifier or additional 

defrost cycle to minimize condensation and freezing for 

freezer applications. We recommend the air curtain unit 

to not replace doors but work in conjunction with door 

opening sequence cycle. Contact factory for details. 

 

 

CAUTION

 

 

The appliance is not to be used by persons (including 

children) with reduced physical, sensory,  or mental 

capabilities, or lack of experience and knowledge, unless 

they have been given supervision or instruction. Children 

are not to play with the appliance. 

 

DISCLAIMER 

 

Mars reserves the right to change specifications and 

product design without notice. Such revisions do not 

entitle the buyer to corresponding changes, 

improvements, additions, or replacements for previously 

purchased equipment.

 

I.  For products with control panels, turn the HOA (Hand-

On-Auto) selector switch to “On” position and open the 

door to energize the product. For products without a 

control panel or an On/Off switch, open the door to 

energize the product. 

J.  If heated products are installed, reference 

Heated 

Products Supplement

K.  For three phase units, verify direction of rotation of 

blower wheels (note direction arrows on the blower 

wheel housing). Correct if needed by changing 

polarity of three phase power. 

L. 

VERY IMPORTANT

 Using a clamp meter, measure 

the amperage to each motor and ensure that they do 

not exceed the amperage listed on the product label. 

M.  If applicable, adjust the air intake grille(s) such that the 

output air stream reaches the floor. For temperature 

control and environmental separation applications, the 

air stream should reach the floor with sufficient 

strength to create an air seal around the door opening 

without creating turbulent mixing of the inside and 

outside air. For flying insect control applications, the 

air stream should reach the floor with maximum 

strength.  If after proper installation and adjustment, 

the product appears to be producing too little or too 

much air for the application, contact the manufacturer.  

 

    WARNING 

To reduce the risk of fire, electrical shock, or injury to 

persons, observe the following: 

A. Maintenance is to be performed only by qualified 

personnel who are familiar with local codes and 

regulations and are experienced with this type of 

product. 

B. Before servicing or cleaning the product switch power 

off at service panel and lock service panel to prevent 

power from being switched “ON” accidentally.

 

Summary of Contents for LPN2 Series

Page 1: ...stamped air intake screen s The LPV2 models can be configured with an aluminum mesh filter s as an option The LPN2 models 25 and all LPN F models come standard with an aluminum mesh air intake filter...

Page 2: ...l other accessories from interior of unit prior to operating Severe unit damage will occur if these items are not removed prior to operation 2 Lay unit on its top with directional vanes pointing up an...

Page 3: ...uing with the start up it is important to recognize the safety controls furnished with the unit WARNING The following items must all be completed by a qualified installer and checked off when complete...

Page 4: ...nimize condensation and freezing for freezer applications We recommend the air curtain unit to not replace doors but work in conjunction with door opening sequence cycle Contact factory for details CA...

Page 5: ...on on intake or discharge Remove obstruction or move air curtain Power leads out of polarity Switch power leads to correct polarity 3 phase models only Blower motor rotating below normal speed Apply p...

Page 6: ...ma 1 1 115 1 1 6 2 4 03 015 7124 1096 Genteq Nema 1 1 208 230 1 6 5 9 2 03 015 Nidec Nema 1 1 208 230 1 4 3 6 5 03 014 K55BWJZB 2362 US Nema 1 1 115 1 1 2 1 03 015 US Nema 1 1 208 230 1 3 2 6 3 Black...

Page 7: ...omer may be responsible for transportation charges associated with replacement of failed part Mars does not warrant uninterrupted or error free operation of Mars product Under no circumstance is Mars...