Service Manual -
B-VMHxxAV-1
Troubleshooting
Note: The picture and the value are only for reference, actual condition and specific value may vary.
8.3 IPM Continuity Check
WARNING
Electricity remains in capacitors even when the power supply is off.
Ensure the capacitors are fully discharged before troubleshooting.
1. Turn off outdoor unit and disconnect power supply.
2. Discharge electrolytic capacitors and ensure all energy-storage unit has been discharged.
3. Disassemble outdoor PCB or disassemble IPM board.
4. Measure the resistance value between P and U(V, W, N); U(V, W) and N.
Digital tester
Resistance value
Digital tester
Resistance value
(+)Red
(-)Black
∞
(Several M
Ω
)
(+)Red
(-)Black
∞
(Several M
Ω
)
P
N
U
N
U
V
V
W
W
-