Service Manual -
B-VMHxxAV-1
Troubleshooting 26
Index:
1. Indoor DC Fan Motor(control chip is in fan motor)
Power on and when the unit is in standby, measure the voltage of pin1&pin2 of CN15, pin3 of CN34 in fan motor
connector. If the value of the voltage is not in the range showing in below table, the PCB must has problems and need to
be replaced.
CN34
NO.
Color
Signal
Voltage
1
/
/
2
Black
GND
3
Orange
PWM
5-12VDC
4
Blue
FG
CN15
NO.
Color
Signal
Voltage
1
Yellow
208/230VAC
2
Black
208/230VAC
3
Yellow-Green
GND
2. Outdoor DC Fan Motor (control chip is in outdoor PCB)
Release the UVW connector. Measure the resistance of U-V, U-W, V-W. If the resistance is not equal to each other, the
fan motor must has problems and need to be replaced. otherwise the PCB must has problems and need to be replaced.