IPI Electronic Ignition System
Electrical Supply in Series: The entire IPI system can be powered by a
single power source (i.e. by the AC Adapter). This is advantageous if you
do not want to supply extra batteries. To achieve this simply connect the
AC Adapter into the Remote Control wiring harness instead of the main
IPI harness. From the Remote wiring harness, use its male plug-in
connector and connect it to the female plug-in in the main IPI harness.
Now the circuit is complete. So the way it works is that electrical power is
supplied to the Remote Receiver module and then proceeds to the Main
IPI module. Furthermore, note that a Backup Battery Pack is not required
in this configuration. Instead, batteries in the Remote Receiver act as the
backup supply.
NOTE:
The Remote Receiver module can also be
located outside of the appliance to a maximum of 6ft
away installed in a certified deep wall switch electrical
box (2-3/4” depth). For this configuration an extension
wiring harness (P/N: 1001-P904SI) is required.
Junction Box Location
The electrical junction box must be located on the outside of the appliance near the bottom as shown in the illustration
to the right. Be sure to follow local electrical codes when install the junction box
IPI Box Location