3. Connect the new pressure sensor.
a. Put the pressure sensor cables through the hole in the
internal housing.
b. Connect the cables to the white connector according
to the order on the picture (view of side with clips up
ward).
Updating the Depth Coefficients
About this task
Note:
Marport offices only
Procedure
1. From a web browser, go to Marport Authorized Service Provider (MASP) website:
.
2. Go to
Components > Add-ons > Pressure device
and enter the pressure sensor
serial number in the search box.
3. From the pressure sensor page, click
Download MOSA File
.
4. Connect the sensor to Mosa2.
5. From Mosa2, click
Menu > Expert Mode
and enter the password
copernic
.
6. Press c A or click
Menu
and click
User Mode > Advanced
7. In
Measurements
page, click
in
Depth
.
8. Click and select the XML file you downloaded.
XXL bottle
| V1 | Replacing Parts
25