2
INSTALLATION
Service Connections
SERVICE CONNECTIONS
E
Electrical Connection - Ø 1-1/8” hole for electrical
connection. Rating to be as specified on data plate.
D
Drain Connection - 1/2” NPT
INSTALLATION CLEARANCE
Left Side
Right Side
Rear
0” (0mm)
0” (0mm)
3” (76mm)
ELECTRICAL CHARACTERISTICS
Volts
AC
TS-3E (9kW)
TS-5E (15kW)
1 PH
9kW
1 PH
6kW
3 PH
9kW
3 PH
6kW
1 PH
15kW
1 PH
10kW
3 PH
15kW
3 PH
10kW
208 43.3 28.9 25.0
--
72.1 48.1 41.6
--
220 40.9 27.3 23.6
--
68.2 45.5 39.4
--
240 37.5 25.0 21.7
--
62.5 41.7 36.0
--
380
--
--
13.7
--
--
--
22.8
--
415
--
--
12.5
--
--
--
20.9
--
480
--
--
10.8
--
--
--
18.0
--
600
--
--
8.7
--
--
--
14.4
--
16.88 [429]
25 [635]
8.5
[216]
4 [102]
2 [51]
24
[610]
D
E
20 [508]
D
4 [102]
2 [51]
VENT
E
3 [76]
TS-3E
19.13
[486] TS-5E
25.5
[648]
19.25 [489]
2 [51]
DIMENSIONS ARE IN INCHES [MM]
Figure 1