3-11
Nº326S Preamplifier
Setup Menu
Setup Menu Parameters
Default
Possible
Parameter
Setting
Settings
Mute
-20.0dB
-10.0dB to -80.0dB
MaxVol
80.0dB
40.0dB to 80.0dB
Trig.
12v,L
12v,L; 5v,P
Sw
x.xx
x.xx
Mute
Determines the amount of master volume level attenuation that
–10.0dB to –80.0dB
occurs when mute is activated with the front panel or remote
control
mute button
. The mute level can be set in 0.1dB increments
between –10.0dB and –80.0dB. The factory-default mute level is
–20.0dB.
MaxVol
Determines the maximum master volume level setting in 0.1dB
40.0dB to 80.0dB
increments between 40.0dB and 80.0dB. The factory-default maxi-
mum master volume level is 80.0dB.
Trig.
Configures the
trigger output
signal. Selecting the 12v,L setting
12v,L; 5v,P
configures the
trigger output
connector to send a 12V, level
(constant) signal to the connected component whenever the
Nº326S is taken out of standby. This signal is not present when
the Nº326S is placed into standby. Selecting the 5v,P signal
configures the
trigger output
connector to send a 5V pulse signal,
similar to that of a momentary contact switch, to the
connected component whenever the
standby button
is pressed.
This signal is only present when the
standby button
is pressed.
Sw
Indicates the current software version operating in the Nº326S,
Non-adjustable
allowing for quick comparison between the current software
version and most current software version available. Software
upgrades can be performed with the
RS-232
port, allowing software
to be upgraded without disassembling the Nº326S or disconnecting
it from other components.
(continued)