23
22
5. Remove Lamp Shield “Boot”.
6. Using an “Allen” wrench, unscrew end bolt
and carefully slide fluorescent lamp from
Lamp Shield.
7. Carefully grasp lamp at one end. Press out
and lift up to remove from Inner Housing
Mounts. Discard used lamp.
8. Install new lamp by gently pressing ends
into Inner Housing Mounts. Reverse process
to restore lamp to operation.
SPECIAL SERVICING-U.V. DISINFECTION UNIT
Every six months…
Clean UV Disinfection Unit Quartz Sleeve.
The Quartz Sleeve will develop a layer of film on its surface which can reduce UV
Lamp effectiveness. Film should be removed on a regular basis. Consult the enclosed
UV Lamp Operations Manual for specific instructions.
NOTE:We strongly recommend that all servicing of the UV Disinfection Unit for the
Marineland ML-24BW be performed by a qualified technician or trained associate.
If you or your staff are not familiar with aquatic UV Disinfection Unit design and
installation, call Marineland Customer Service for a service referral.
Replace UV Disinfection Unit Lamp.
The UV Lamp has a useful service life of about 9 months.After this time– whether
it continues to appear functional or not – it must be replaced. Consult the enclosed
Operations Manual for instructions.
NOTE: Replacement Lamp provided with your new system. When changing UV
Lamp, always clean Quartz Sleeve.
As needed…
Clean Spray Bar.
When water flow through Spray Bar is reduced…
1. Shut down system.
2. Using adjustable wrench, unscrew (A) and remove Spray Bar Access Plug (B).
3. Turn on system and wait for water to flush through.
4. Shut down system, replace Access Plug.
5. Restart system.
IMPORTANT:
To prolong the life of the UV Disinfection Unit and avoid
leaving fingerprints on the UV Lamp, we strongly recommend that you
wear cotton gloves at all times during servicing of UV Disinfection Unit.
NEVER look directly into UV Lamp while in operation... eye injury may occur.
NEVER restore power while UV Lamp is separated from Treatment Chamber. Skin
damage and/or injury may result.