background image

4

5

PARTS DIAGRAM AND IDENTIFICATION

MAGNUM PARTS IDENTIFICATION

AND REPLACEMENT PARTS LISTS

220

350

350D

Item No.

Key

Description

PR 1401

1

• • •

Outlet Tube with Split Flow Diffuser

PR 1402

2

• • •

Intake Tube with Strainer

PR 1404

3

• • •

Tube Retainer Bracket with Bow

PR 1410

4

• • •

Hose Retainer Bands  Pkg-4

PR 1411

5

Canister Cover w/Intake Diffuser

PR 1412

5

• •

Canister Cover w/Intake Diffuser

PR 1413

6

• • •

O-Ring Cover Seal

PR 1414

7

• • •

Rubber Gasket Set

PR 1416

8

• • •

Carrying Handle

PR 1420

9

• • •

Core for Micron Cartridge

PR 1421

10

Core Set for Carbon Container

PR 1422

11

Carbon Container Screen

PR 1430

12

• • •

Impeller Exhaust Tube

PR 1437

13

• • •

Clip and Pin Set  Pkg-4

PR 1450

n/s

O-RINGS - MAGNUM Quick Disconnect Valve  Pkg-4

PA 1462

14

• • •

Inlet Strainer 

PR 1469

15

Magnetic Impeller Assembly for 220

PR 1470

16a

• •

Magnet only, for 350

PR 1472

16b

• •

Impeller and Shaft Assy. w/o Magnet

PR 1474

17

• • •

Impeller Housing

PR 1475

18

• • •

Adhesive Foot Pads  Pkg-14

PR 1476

19

• • •

Canister w/Clips

PR 1477

20

• •

Sealed Motor & Switch Assembly

PR 1478

20

Sealed Motor & Switch Assembly

PR 1479

21

• • •

Stabilizer Leg

PR 1480

22

• • •

Sump Cap

PR 0010

n/s

• • •

UGF Adapter

PR 1517

23

• • •

Split Flow Diffuser

PA 1341

24

3/4” Ext. Tube w/Coupling

PA 0140

25

• •

Micron Cartridge

PA 0145

26

Carbon/Media Container

PA 0114

27

Bonded Filter Sleeve

PR 1590

• • •

Silicone Lubricant

See  Key  for Parts I.D.

MAGNUM 350

Impeller Parts

Assembly

3

2

1

23

24

4

5

6

7

9

12

17

8

15

19

22

20

21

18

13

11

10

16b

16a

14

If parts are unavailable from store where filter was purchased, call our Customer
Service Department at (800) 322-1266, Monday - Friday from 8AM - 5PM 
(Pacific Time). Please have your model number, part number and MasterCard or
VISA ready when ordering.

Note: All items bearing a “PA” designation are considered accessories rather than

replacement parts. They may be purchased at your local Marineland outlet.

25

26

27

NOTE: 

Some parts and their assembly differ for Model 220, 350 

or 350D. Always follow instructions specifically for your Model
where indicated

.

Prior to assembly, remove parts bag and filter from display 
box. Inspect each part carefully and note that all parts are 
included according to the diagram. If all is in order, 
fill out the Warranty and Owner Information Card and 
return it to Marineland. If any part is damaged or 
missing, call Marineland Customer Service 
at (800) 322-1266.

Summary of Contents for Magnum 220

Page 1: ...ich is deemed defective in workmanship or materials Please return the unit together with proof of date of purchase to your local dealer or send unit postage paid to MARINELAND AQUARIUM PRODUCTS 6100 Condor Drive Moorpark CA 93021 Damage or injuries resulting from negligence or misuse are not covered by this warranty Incidental or consequential damages are specifically excluded This warranty gives ...

Page 2: ...he receptacle If the plug or receptacle does get wet DON T unplug the cord Disconnect the fuse or circuit breaker that supplies power to the appliance Then unplug and examine for presence of water in the receptacle 2 Close supervision is necessary when any appliance is used by or near children 3 To avoid injury do not contact moving parts or hot parts such as heaters reflectors lamp bulbs etc 4 Al...

Page 3: ...particles eliminating the need for diatomite powder and the more it filters the more efficient it becomes And the Magnum 350 is readily convertible from water polishing to everyday 2 stage filtration via the Magnum Carbon Media Container sold separately The Magnum 350 Deluxe includes both the continuous duty Carbon Media Container and quick clean Micron Cartridge as standard equipment plus an Inta...

Page 4: ...izer Leg PR 1480 22 Sump Cap PR 0010 n s UGF Adapter PR 1517 23 Split Flow Diffuser PA 1341 24 3 4 Ext Tube w Coupling PA 0140 25 Micron Cartridge PA 0145 26 Carbon Media Container PA 0114 27 Bonded Filter Sleeve PR 1590 Silicone Lubricant See Key for Parts I D MAGNUM 350 Impeller Parts Assembly 3 2 1 23 24 4 5 6 7 9 12 17 8 15 19 22 20 21 18 13 11 10 16b 16a 14 If parts are unavailable from store...

Page 5: ...2a Attach Intake Extension if necessary If using Magnum to power an under gravel filter Strainer will not be needed Slide UGF Adapter provided over end of Intake Tube and rest Adapter on top of Lift Tube Figure 2b Split Flow Diffuser Outlet Tube Figure 3 Figure 1 STEP 3 INSTALL SPLIT FLOW DIFFUSER Install Split Flow Diffuser carefully on Outlet Tube as shown Figure 3 Tube lip must be positioned in...

Page 6: ...e Hose ends should touch cover Roll Hose Retainer Bands into place Figure 9b 8 9 STEP 6 POSITION MOTOR AND CANISTER Apply self adhesive Rubber Foot Pads to the underside of the Motor Assembly and extendible Stabilizer Legs in depressions provided Slide legs into position on underside of Motor Housing and extend as desired for stability Figure 6 Place unit Canister with Motor Assembly in well venti...

Page 7: ...nless steel Clips and remove Canister Cover by pushing up on Cover Tabs Figure 12 Grasp Carrying Handle and lift Canister off Motor Housing Assembly Figure 11 Figure 11 Motor Housing Assembly STEP 1 OPEN CANISTER AND REMOVE FROM MOTOR BASE Figure 10 Outlet Tube Hose Retainer Bands Intake Tube CAUTION When Cover is removed water can siphon onto floor if Intake and Outlet Tubes are not removed or va...

Page 8: ... cartridge over top of Impeller Housing and Rubber Gasket IMPORTANT Unlike other carbon Black Diamond Activated Carbon is graded for uniform particle size Grading prevents smaller media particles from escaping and seriously damaging Impeller Assembly Rigid Core Figure 15 Micron Cartridge Figure 17 Figure 18 CAUTION DO NOT force Canister onto Motor Assembly DO NOT start Motor yet NEVER run Motor wh...

Page 9: ...er flow excessive mechanical or water noise cloudy and or bad smelling water require immediate attention To ensure optimum filter performance and maintain full flow regular cleaning and media changes are recommended as necessary at least every 2 4 weeks Significantly reduced water flow is a sure sign of clogging media and should be dealt with immediately Always rinse or replace Filter Sleeve when ...

Page 10: ...rn parts immediately 6 Gently clean flat Rubber Gaskets with warm water only 7 Wash O Ring Seating Area on Canister and Cover Wet O Ring before reinstalling 8 Reassemble system and return to operation as previously instructed CAUTION IF YOU HAVE INSTALLED QUICK DISCONNECT VALVES always close all valves before disconnecting MAGNUM QUICK DISCONNECT VALVES Installation Operation Maintenance Magnum Qu...

Page 11: ...agnum Canister When servicing Magnum Turn off Magnum Close all valves Figure 22 Slide Lock Ring up twist Coupling and separate Figure 19 NOTE Coupling barrel may remain with either end of valve when disconnected This is normal and will not affect performance Lift Canister with Cover in place from motor for maintenance Reconnect by reversing order of previous steps NOTE To ensure that Couplings are...

Page 12: ...xi Brush accessory PA0554 Clean or replace Rite Size Flter Sleeve Carbon Media Container or Micron Cartridge SYMPTOM COMMENTS SOLUTION If air accumulates in Canister during operation If leakage occurs at hose connections If leakage occurs along rim of Canister Cover Move Intake away from airstone bubbles or other air source Check position of hoses and retainer bands to ensure that air is not being...

Reviews: