Please follow these instructions for proper regular care each time the
Magnum media is serviced:

1. Shut down system and remove Canister.

2. Change media:

CARBON/MEDIA CONTAINER

Remove media and rinse container thoroughly. Refill container
with Black Diamond Activated Carbon and 

rinse carbon 

thoroughly.

Rinse or replace Rite-Size Filter Sleeve.

Environmental Tip

...Used activated carbon can be added to garden soil to aid

in plant fertilization (does not apply to media used with fish medications).

MICRON CARTRIDGE

Remove and clean Cartridge – 

never brush or machine wash.

Rinse off all visible dirt. Mix a solution of one part chlorine 
bleach to three parts water. Immerse cartridge completely in 
solution and soak overnight. Rinse thoroughly until chlorine 
smell disappears.

For Best Results

...Purchase a second Micron Cartridge for alternate use while

original Cartridge soaks and dries thoroughly.

3. Clean Canister thoroughly, especially sump area.
4. Clean Impeller Assembly and inspect for wear and smooth 

rotation. If excess wear is noted, replace worn parts immediately.

6. Gently clean flat Rubber Gaskets with warm water only.  
7. Wash O-Ring Seating Area on Canister and Cover.Wet O-Ring

before reinstalling.

8. Reassemble system and return to operation as previously instructed.

CAUTION: 

IF YOU HAVE INSTALLED QUICK DISCONNECT VALVES…

always close all valves before disconnecting.

!

MAGNUM QUICK DISCONNECT VALVES

Installation/Operation/Maintenance

Magnum Quick Disconnect Double Valves are featured as standard equipment
with the Magnum 350 Deluxe Convertible Canister Filter and Magnum 350
PRO System. Single and Double Valves may be purchased separately for use
with the Magnum 220 (1/2” Valves) and 350 (5/8” Valves).

INSTALLATION

Install 

Valves 

after completing hose installation (Figure 19). 

Begin installation on hoses leading from top of 

Magnum Canister

.

Choose convenient, easily accessible location along tubes for valves.
Cut and remove 5” of hose where valves are to be installed.

NOTE: 

If installing Single Valves make sure the ON/OFF Flow

Regulator is located on the Upper Hose Section.

Figure 19

Upper

Hose to

Aquarium

Lower

Hose to

Magnum

Compression 

Nut

Lock

Compression 

Nut

Coupling

Barrel

ON/OFF or FLOW

REGULATOR

ON/OFF or

FLOW REGULATOR

Double Valves Shown

On

Position

Off

Position

Off

Position

Summary of Contents for Magnum 220

Page 1: ...ich is deemed defective in workmanship or materials Please return the unit together with proof of date of purchase to your local dealer or send unit postage paid to MARINELAND AQUARIUM PRODUCTS 6100 Condor Drive Moorpark CA 93021 Damage or injuries resulting from negligence or misuse are not covered by this warranty Incidental or consequential damages are specifically excluded This warranty gives ...

Page 2: ...he receptacle If the plug or receptacle does get wet DON T unplug the cord Disconnect the fuse or circuit breaker that supplies power to the appliance Then unplug and examine for presence of water in the receptacle 2 Close supervision is necessary when any appliance is used by or near children 3 To avoid injury do not contact moving parts or hot parts such as heaters reflectors lamp bulbs etc 4 Al...

Page 3: ...particles eliminating the need for diatomite powder and the more it filters the more efficient it becomes And the Magnum 350 is readily convertible from water polishing to everyday 2 stage filtration via the Magnum Carbon Media Container sold separately The Magnum 350 Deluxe includes both the continuous duty Carbon Media Container and quick clean Micron Cartridge as standard equipment plus an Inta...

Page 4: ...izer Leg PR 1480 22 Sump Cap PR 0010 n s UGF Adapter PR 1517 23 Split Flow Diffuser PA 1341 24 3 4 Ext Tube w Coupling PA 0140 25 Micron Cartridge PA 0145 26 Carbon Media Container PA 0114 27 Bonded Filter Sleeve PR 1590 Silicone Lubricant See Key for Parts I D MAGNUM 350 Impeller Parts Assembly 3 2 1 23 24 4 5 6 7 9 12 17 8 15 19 22 20 21 18 13 11 10 16b 16a 14 If parts are unavailable from store...

Page 5: ...2a Attach Intake Extension if necessary If using Magnum to power an under gravel filter Strainer will not be needed Slide UGF Adapter provided over end of Intake Tube and rest Adapter on top of Lift Tube Figure 2b Split Flow Diffuser Outlet Tube Figure 3 Figure 1 STEP 3 INSTALL SPLIT FLOW DIFFUSER Install Split Flow Diffuser carefully on Outlet Tube as shown Figure 3 Tube lip must be positioned in...

Page 6: ...e Hose ends should touch cover Roll Hose Retainer Bands into place Figure 9b 8 9 STEP 6 POSITION MOTOR AND CANISTER Apply self adhesive Rubber Foot Pads to the underside of the Motor Assembly and extendible Stabilizer Legs in depressions provided Slide legs into position on underside of Motor Housing and extend as desired for stability Figure 6 Place unit Canister with Motor Assembly in well venti...

Page 7: ...nless steel Clips and remove Canister Cover by pushing up on Cover Tabs Figure 12 Grasp Carrying Handle and lift Canister off Motor Housing Assembly Figure 11 Figure 11 Motor Housing Assembly STEP 1 OPEN CANISTER AND REMOVE FROM MOTOR BASE Figure 10 Outlet Tube Hose Retainer Bands Intake Tube CAUTION When Cover is removed water can siphon onto floor if Intake and Outlet Tubes are not removed or va...

Page 8: ... cartridge over top of Impeller Housing and Rubber Gasket IMPORTANT Unlike other carbon Black Diamond Activated Carbon is graded for uniform particle size Grading prevents smaller media particles from escaping and seriously damaging Impeller Assembly Rigid Core Figure 15 Micron Cartridge Figure 17 Figure 18 CAUTION DO NOT force Canister onto Motor Assembly DO NOT start Motor yet NEVER run Motor wh...

Page 9: ...er flow excessive mechanical or water noise cloudy and or bad smelling water require immediate attention To ensure optimum filter performance and maintain full flow regular cleaning and media changes are recommended as necessary at least every 2 4 weeks Significantly reduced water flow is a sure sign of clogging media and should be dealt with immediately Always rinse or replace Filter Sleeve when ...

Page 10: ...rn parts immediately 6 Gently clean flat Rubber Gaskets with warm water only 7 Wash O Ring Seating Area on Canister and Cover Wet O Ring before reinstalling 8 Reassemble system and return to operation as previously instructed CAUTION IF YOU HAVE INSTALLED QUICK DISCONNECT VALVES always close all valves before disconnecting MAGNUM QUICK DISCONNECT VALVES Installation Operation Maintenance Magnum Qu...

Page 11: ...agnum Canister When servicing Magnum Turn off Magnum Close all valves Figure 22 Slide Lock Ring up twist Coupling and separate Figure 19 NOTE Coupling barrel may remain with either end of valve when disconnected This is normal and will not affect performance Lift Canister with Cover in place from motor for maintenance Reconnect by reversing order of previous steps NOTE To ensure that Couplings are...

Page 12: ...xi Brush accessory PA0554 Clean or replace Rite Size Flter Sleeve Carbon Media Container or Micron Cartridge SYMPTOM COMMENTS SOLUTION If air accumulates in Canister during operation If leakage occurs at hose connections If leakage occurs along rim of Canister Cover Move Intake away from airstone bubbles or other air source Check position of hoses and retainer bands to ensure that air is not being...