sMRT V100/V100X User Manual v1.0
MRT Ltd. © 2014
20
Self-test
The sMRT V100/V100X performs a self-test when the
ACTIVATION
SWITCH
is moved from the
[OFF]
position to
[READY]
. Self-test
LED
indications are displayed for several seconds at this point
and may display as follows:
The
LEFT LED
indicates device test status and the
RIGHT LED
indicates GPS test status.
Full system test
1. The
ARMING SWITCH
can be in the
[OFF]
or
[READY]
positions when performing a
full system test.
2. Open the sMRT V100/V100X access
point zip of the PFD. Insert the
TEST
MAGNET
and hold it over the
TEST
SPOT
for three seconds to activate
test mode.
LEFT LED
LED Colour
RIGHT LED
LED Colour
Battery critically low
or VHF transmitter
error; remove device
from service
Solid red
GPS error; remove
device from service
Solid Red
Less than 12 hours
battery life; remove
device from service
Magenta
VHF Self Test OK
Solid Blue
GPS self test OK
Solid Blue
Summary of Contents for sMRT V100