Revision 1.6
Page 23
3.5.4.3.1 OnLevel(s)
This parameter allows you to configure the voltage level on the input signals that corresponds
to an ON status on the input as reported on the network. You can use any of the following
settings:
•
High
– a high voltage level on the input is represented as an ON value on the network.
A high impedance or a low voltage level on the input is represented as an OFF value on
the network.
•
Low
– a low voltage level on the input is represented as an ON value on the network. A
high impedance or a high voltage level on the input is represented as an OFF value on
the network.
•
Both
– a high voltage level or a low voltage level on the input is represented as an ON
value on the network. A high impedance on the input is represented as an OFF value on
the network.
3.5.4.3.2 State
This read-only field represents the current state of the input signal as reported on the network.
3.5.5 Advanced
The Advanced tab is used to configure and observe parameters that do not normally require
changing.